Digitala Vetenskapliga Arkivet

Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Evaluation of Knee Ligament Injuries in Occupants of Heavy Goods Vehicles by Simulating Frontal Impacts using THUMS HBM
KTH, School of Engineering Sciences in Chemistry, Biotechnology and Health (CBH).
2019 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesisAlternative title
Utvärdering av knäligamentskador hos åkande i tunga fordon genom att simulera frontala islag hos THUMS HBM (Swedish)
Abstract [en]

INTRODUCTION. Frontal collisions have been observed to cause the severe injuries on heavy goods vehicle occupants, and the lower extremities have been frequently injured. Injuries of knee joints are rarely life threatening, however they tend to give long-term consequences.

AIM. Evaluate non-lethal frontal impacts towards the knee joint of Total Human Model for Safety (THUMS) v4.0 using a cylindrical barrier. The main objectives are to 1) create local injury risk functions of the knee ligaments restraining frontal impacts, 2) simulate frontal impacts towards the knee joints of THUMS and3) prepare the Hybrid III (HIII)-model for corresponding frontal impacts conducted on THUMS. The intention is for future HIII-simulations to be cross-correlated with the responses from THUMS for the ability to estimate knee ligament strains by investigating impacts on HIII.

METHODS. 1) Ligament risk curves of PCL, MCL and LCL were formulated by assembling mean strain threshold values and standard deviations from literature. Virtual values were generated from these pooled strain thresholds, creating the risk curves. 2) THUMS lower body was impacted by a cylindrical steel barrier at four different locations - middle of patella, middle of knee joint, upper tibia and below tibia tuberositas. Four impact velocities ranging from 8-14 km/h were used at each location, giving a total of 16 impacts. 3) The HIII-model was prepared by removing the upper body and inserting the cylindrical steel barrier into the model file.

RESULTS. The strain threshold at 50% rupture risk for PCL resulted in 23.6±4.4%, 34.2±6.0% for MCL and 26.6±6.5% for LCL. The simulated THUMS PCL strains reached between 36%-58% for the highest velocity at the impact locations where tibia was involved. Both MCL and LCL gave an approximate 5% strain outcome. The resultant knee displacement for these impacts ranged between 22 mm - 32 mm. The knee displacements at the PCL strain threshold ranged between 14 mm - 16 mm.

DISCUSSION and CONCLUSION. Most of the maximal PCL strains exceeded the PCL threshold with large margins. However, the knee displacement at the PCL strain threshold resulted in outcomes comparable to the thresholds used for HIIImodel. These results supported the obtained PCL threshold to be within a reasonable range.

Place, publisher, year, edition, pages
2019. , p. 95
Series
TRITA-CBH-GRU ; 2019:101
Keywords [en]
Frontal impacts, Cumulative injury risk curve, Ligament material curves, Total Human Model for Safety (THUMS), Hybrid III- model (HIII), Heavy Goods Vehicles (HGV), Validation, Knee joint, Posterior cruciate ligament (PCL), Medial collateral ligament (MCL), Lateral collateral ligament (LCL).
National Category
Medical Engineering
Identifiers
URN: urn:nbn:se:kth:diva-262667OAI: oai:DiVA.org:kth-262667DiVA, id: diva2:1361801
External cooperation
Scania CV AB
Subject / course
Medical Engineering
Educational program
Master of Science - Medical Engineering
Supervisors
Examiners
Available from: 2019-10-17 Created: 2019-10-17 Last updated: 2022-06-26Bibliographically approved

Open Access in DiVA

Nusia_MasterThesis(8212 kB)480 downloads
File information
File name FULLTEXT01.pdfFile size 8212 kBChecksum SHA-512
f0d66c30669e66ceb4d9dca3a53ca6f29f05fb635b3f9f58c9a623d74ffc380458e5a8370d19590e75e0814e171492e628e2c6a6d4c70f4469077e058d263494
Type fulltextMimetype application/pdf

By organisation
School of Engineering Sciences in Chemistry, Biotechnology and Health (CBH)
Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 480 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 698 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf