Development of antibacterial Ti-Cux alloys for dental applications: effects of ageing for alloys with up to 10wt%Cu
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Engineering Sciences, Applied Materials Sciences. (Materials in Medicine)ORCID iD: 0000-0001-6057-7571
Advanced Materials Division, Mintek, Randburg 2124, South Africa; School of Chemical and Metallurgical Engineering, and DST-NRF Centre of Excellence in Strong Materials, hosted by the University of the Witswatersrand, Johannesburg 2000, South Africa.
School of Chemical and Metallurgical Engineering, and DST-NRF Centre of Excellence in Strong Materials, hosted by the University of the Witswatersrand, Johannesburg 2000, South Africa.
School of Chemical and Metallurgical Engineering, and DST-NRF Centre of Excellence in Strong Materials, hosted by the University of the Witswatersrand, Johannesburg 2000, South Africa.
Show others and affiliations
2019 (English)In: Materials, ISSN 1996-1944, E-ISSN 1996-1944, Vol. 12, no 23, article id 4017Article in journal (Refereed) Published
Abstract [en]

Peri-implantitis, a disease caused by bacteria, affects dental implants in patients. It is widely treated with antibiotics, however, with growing antibiotic resistance new strategies are required. Titanium-copper alloys are prospective antibacterial biomaterials, with the potential to be a remedy against peri-implantitis and antibiotic resistance. The aim of this study was to investigate Ti-Cux alloys, exploring how Cu content (up to 10 wt%) and ageing affect the material properties. Electron microscopy, X-ray diffraction, hardness testing, bacteriological culture, and electrochemical testing were employed to characterize the materials. It was found that alloys with above 3 wt% Cu had two phases and ageing increased the volume fraction of Ti2Cu. An un-aged alloy of 5 wt% Cu showed what could be Ti3Cu, in addition to the α-Ti phase. The hardness gradually increased with increased Cu additions, while ageing only affected the alloy with 10 wt% Cu (due to changes in microstructure). Ageing resulted in faster passivation of the alloys. After two hours the aged 10 wt% Cu alloy was the only material with an antibacterial effect, while after six hours, bacteria killing occurred in all alloys with above 5 wt% Cu. In conclusion, it was possible to tune the material and antibacterial properties of Ti-Cux alloys by changing the Cu concentration and ageing, which makes further optimization towards an antibacterial material promising.

Place, publisher, year, edition, pages
Switzerland: MDPI, 2019. Vol. 12, no 23, article id 4017
Keywords [en]
titanium alloys, copper, Ti2Cu, biomaterial, antibacterial
National Category
Medical Materials
Identifiers
URN: urn:nbn:se:uu:diva-395300DOI: 10.3390/ma12234017OAI: oai:DiVA.org:uu-395300DiVA, id: diva2:1361791
Funder
The Swedish Foundation for International Cooperation in Research and Higher Education (STINT), SA2017-7127Available from: 2019-10-16 Created: 2019-10-16 Last updated: 2020-01-13Bibliographically approved
In thesis
1. Development of titanium-copper alloys for dental applications
Open this publication in new window or tab >>Development of titanium-copper alloys for dental applications
2019 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Titanium alloys find wide application in the medical implants industry, which includes areas of orthopaedic and dental implants. The reason for the popularity of the material is high mechanical strength, low density, and reported growth of bone onto the material, as well as corrosion resistance. Despite the general success of titanium materials, a drawback is that it is vulnerable to bacterial colonization, which can cause implant failure through inflammatory diseases. Peri-implantitis is one such disease, which can lead to irreversible bone loss and subsequently implant instability.

This thesis focuses on the use of copper (Cu) as an antibacterial element in titanium alloys, where the purpose is designing inherently antibacterial materials.

With an understanding that copper can reduce bacterial populations by ion release of Cu into solutions, as well as by direct contact of bacteria with Cu surfaces: studies on the effect of Cu ions on bacteria and cells were conducted, in addition to studies on Ti-Cux alloys.

Varying Cu concentrations in solution were introduced to bacteria (Staphylococcus epidermidis) and cells (MC3T3 murine calvarial osteoblasts), and it was found that the lethal dosage for Cu ions was in the range from 9x10-5 to 9x10-6 g/ml, for bacteria and cells. The Cu ions were also found to cause a stress response for this bacteria at concentrations between 9x10-6 to 9x10-7 g/ml, and recommended to be avoided for implant materials.

For Ti-Cux binary alloys, studies established that a 10wt%Cu alloy, which released 9x10-8 g/ml, reduced the bacterial population by 27 % in 6 hours in a direct contact test. This alloy was found to be composed of intermetallic (Ti2Cu) and hexagonal closed packed titanium (HCP-Ti) crystals. A separate study on aged heat treated Ti-Cux alloys, showed that an additional phase of Ti3Cu was present in lower volume fraction. The aged alloys of Ti-Cux showed higher volume fraction of Ti2Cu but only a slightly higher antibacterial ability, compared to those without ageing. The hardness of the Ti-Cux alloys was however detrimentally affected by ageing, especially for the 10wt%Cu alloy.

Investigations on the alloying of Cu with an existing implant alloy, Ti-10wt%Ta-1.6wt%Nb-1.7wt%Zr (TNTZ), was also performed and at higher wt%Cu alloys with three-phased microstructures were present. Alloying of Cu in the TNTZ material increased hardness and with further development of this novel alloy, a potential biomaterial for clinical applications could be designed.

In conclusion, the results of this thesis demonstrate that the use of Cu in proximity to cells and bacteria requires dose dependent consideration for material design, so that antibacterial materials can be developed that do not harm tissue. The appropriate design of alloys can also be performed so as to allow antibacterial ability to be achieved, along with ensuring appropriate mechanical and corrosion properties. Furthermore, Cu as an antibacterial element can be alloyed into various titanium alloy systems and with further development in this area; antibacterial alloys could benefit the implant industry and patients alike.

Place, publisher, year, edition, pages
Uppsala: Acta Universitatis Upsaliensis, 2019. p. 65
Series
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology, ISSN 1651-6214 ; 1868
Keywords
Titanium, copper, antibacterial, Ti2Cu, biomaterials, Staphylococcus epidermidis, MC3T3 cells
National Category
Medical Materials
Identifiers
urn:nbn:se:uu:diva-395303 (URN)978-91-513-0782-4 (ISBN)
Public defence
2019-12-13, Häggsalen, Ångströmlaboratoriet, Lägerhyddsvägen 1, Uppsala, 13:15 (English)
Opponent
Supervisors
Available from: 2019-11-18 Created: 2019-10-17 Last updated: 2019-11-18

Open Access in DiVA

fulltext(7317 kB)5 downloads
File information
File name FULLTEXT01.pdfFile size 7317 kBChecksum SHA-512
d4a6b48050650cd4342ad6ae45b1146fb86c42df026e9dce11577a105095c0362f12ec8823936030dedbf4d06446af1ef6a5eeadbb325c3adb0e92d222a2a9bb
Type fulltextMimetype application/pdf

Other links

Publisher's full text

Search in DiVA

By author/editor
Fowler, LeeEngqvist, HåkanNorgren, SusanneÖhman-Mägi, Caroline
By organisation
Applied Materials Sciences
In the same journal
Materials
Medical Materials

Search outside of DiVA

GoogleGoogle Scholar
Total: 5 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 38 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf