Övervakning av desinfektionseffekt i vattenrenare för dialys
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.
2019 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesisAlternative title
Monitoring disinfection effect in water purification systems for dialysis (English)
Abstract [sv]

Dialys är en medicinteknisk teknik som används för att rena blod vid nedsatt njurfunktion. Dialysvätska är en viktig komponent i utrustningen. Syftet med examensarbetet var att utvärdera förbättrade rutiner för kvalitetskontroll av vattnet som används för tillredning av dialysvätskan.

Ett program för övervakning av desinfektionseffekt i vattenrenare för dialys har utvecklats i Microsoft Visual Studio, med Windows Forms som plattform och kod skriven i C#. Mjukvaran övervakar konduktivitet, dagar sedan desinfektion, desinfektionseffekt (A₀), aktivitet hos loggningsprogram samt kontrollprogram.

Larm skickas via mail vid dåliga värden eller fel, samt visas lokalt på dator i form av en textruta.

Ett ytterligare program skapades för att kontrollera att huvudprogrammet är igång, och en varning skickas när aktivitet uteblir under en viss längd.

Utöver övervakning skapades även en grafisk del som tillåter visning av loggade data samt beräknade A₀-värden över tid.

Analys utförs kring möjligheter att bibehålla mikrobiologisk trend med stabilt låg bakterienivå i vattnet vid minskad desinfektionsfrekvens från tre till två gånger i veckan. Provtagningar tyder på att marginal till gränsvärde inte hotas, men mer data behövs för at bekräfta resultatet.

Analys utförs även kring möjligheten att använda beräkning av A₀-värden för att verifiera desinfektionseffekt tidigare än resultat från mikrobiologisk provtagning, vilket resultat från den studie som utförts tyder på är möjligt, med vissa undantag där det inte finns data att förhålla sig till.

Vid användning av mjukvaran rekommenderas fortsatta mikrobiologiska provtagningar.

Abstract [en]

Dialysis is a health technology used for cleaning blood in people with kidney failure. Dialysis fluid is an important component used in the dialysis process. The aim of the project is to evaluate improved quality control routines for the water used in preparation of the dialysis fluid.

A program for monitoring disinfection effect in water purification systems for dialysis has been developed in Microsoft Visual Studio, using Windows Forms as platform and the code was written in C#. The software monitors conductivity, days since last disinfection, effect of disinfection (A₀), activity of logging software as well as control software.

Warnings are sent by mail for bad results or errors, and a message is shown as a textbox locally on the computer running the software.

An additional program was made for monitoring the main programs activity, and a warning is sent after seeing no activity within a time period.

Other than monitoring, the software also has a graphical view allowing the user to view logged data and calculated A₀-values over time.

An analysis is made regarding the possibility to maintain microbiological trend of low amounts of bacteria in water after reducing the disinfection frequency from three to two times a week. Test results indicate that the margin to the maximum allowed value remains on safe levels, but more data is required to confirm the results.

A further analysis is made regarding the possibility to use calculations of A₀-values to verify the disinfection effect earlier than results from microbiological testing. Results from studies indicate that this is possible, but with some exceptions in cases where not enough data is available to draw conclusions.

When using the software, continued microbiological testing is recommended.

Place, publisher, year, edition, pages
2019. , p. 37
Keywords [en]
A0, disinfection, water purification, dialysis
Keywords [sv]
A0, desinfektion, vattenrenare, dialys
National Category
Electrical Engineering, Electronic Engineering, Information Engineering Medical Engineering
Identifiers
URN: urn:nbn:se:umu:diva-163249OAI: oai:DiVA.org:umu-163249DiVA, id: diva2:1350662
External cooperation
Norrlands universitetssjukhus (NUS) avd Medicinsk Teknik - Forskning och Utveckling (MT-FoU)
Subject / course
Elektronik
Educational program
Bachelor of Science Programme in Electronic and Computer Engeneering/ Medical engineering
Presentation
2019-06-04, TC335, 10:00 (Swedish)
Supervisors
Examiners
Available from: 2019-09-12 Created: 2019-09-11 Last updated: 2019-09-12Bibliographically approved

Open Access in DiVA

fulltext(1159 kB)310 downloads
File information
File name FULLTEXT01.pdfFile size 1159 kBChecksum SHA-512
098556c3638721bc5c7f34c535c3986e164a14047cd7af94420b7464c6fa5cb807ee70f383e4b455113c9c50bb021b91f840e8ab1d95745c7103b8e91a5b2a33
Type fulltextMimetype application/pdf

By organisation
Department of Applied Physics and Electronics
Electrical Engineering, Electronic Engineering, Information EngineeringMedical Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 310 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 284 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf