Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Preoperative aortic annulus size assessment by transthoracic echocardiography compared to the size of surgically implanted aortic prostheses
Uppsala Univ Hosp, Dept Cardiol, Uppsala, Sweden.
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Surgical Sciences, Thoracic Surgery.
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Medical Sciences, Clinical Physiology. Uppsala Univ Hosp, Uppsala, Sweden.
2019 (English)In: ECHO RESEARCH AND PRACTICE, ISSN 2055-0464, Vol. 6, no 2, p. 37-41Article in journal (Refereed) Published
Abstract [en]

Objectives: The aortic annulus diameter measured by transthoracic echocardiography yields lower values than by computed tomography, and echo-based selection of transcatheter aortic valve prosthesis size has been implied to result in more frequent paravalvular leakage. We investigated the relation of preoperative annulus diameter by echo with the ring size of the aortic prosthesis chosen by direct assessment during open-heart aortic valve replacement.

Methods: Preoperative annulus diameter by echo (from parasternal long-axis cross-sections of the left ventricular outflow tract and aortic valve) and implanted prosthetic diameter (tissue annulus diameter, determined intraoperatively using a sizing instrument) were compared retrospectively in 285 consecutive patients undergoing open-heart aortic valve replacement.

Results: A total of 285 prostheses (240 biologic and 45 mechanical) were implanted, with prosthetic diameter ranging between 19 and 27 mm. There was a significant linear correlation (P < 0.0001) with r = 0.51, between preoperative annulus diameter by echo (mean 21.8 +/- 2.8 mm) and prosthetic diameter (22.9 +/- 1.7 mm). Preoperative annulus diameter of patients receiving prostheses no. 21, 23 and 25 mm aortic prostheses (the most frequent prosthesis sizes) were significantly different (P < 0.001) from each other. On average, preoperative annulus diameter by echo underestimated prosthetic diameter by a bias of 1.07 mm.

Conclusion: Our data confirm that preoperative echo assessment of the aortic valve may slightly underestimates the optimal surgical prosthesis diameter for the aortic valve annulus.

Place, publisher, year, edition, pages
2019. Vol. 6, no 2, p. 37-41
Keywords [en]
aortic valve, aortic valve replacement, prosthetic valve, echocardiography
National Category
Surgery Cardiac and Cardiovascular Systems
Identifiers
URN: urn:nbn:se:uu:diva-389614DOI: 10.1530/ERP-19-0010ISI: 000471282700009PubMedID: 31082800OAI: oai:DiVA.org:uu-389614DiVA, id: diva2:1338291
Available from: 2019-07-22 Created: 2019-07-22 Last updated: 2019-07-22Bibliographically approved

Open Access in DiVA

fulltext(778 kB)48 downloads
File information
File name FULLTEXT01.pdfFile size 778 kBChecksum SHA-512
6233a140650a42eb9b374a448fb006130055931d8bc6fc9ba0a2091c476a0901ebbaa208c259f2ddded2bf26ef65644375a8a7a0ec6f38052409e59369d52819
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Johansson Hellgren, LailaFlachskampf, Frank A.
By organisation
Thoracic SurgeryClinical Physiology
SurgeryCardiac and Cardiovascular Systems

Search outside of DiVA

GoogleGoogle Scholar
Total: 48 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 75 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf