Active Management of Heat Customers Towards Lower District Heating Return Water Temperature
Linköping University, Department of Management and Engineering, Energy Systems. Linköping University, Faculty of Science & Engineering.
Linköping University, Department of Management and Engineering, Energy Systems. Linköping University, Faculty of Science & Engineering.
2019 (English)In: Energies, ISSN 1996-1073, E-ISSN 1996-1073, Vol. 12, no 10, article id 1863Article in journal (Refereed) Published
Abstract [en]

The traditional way of managing the supply and return water temperatures in a district heating system (DHS) is by controlling the supply water temperature. The return water temperature then becomes a passive result that reflects the overall energy efficiency of the DHS. A DHS with many poorly functioning district heating centrals will create a high return water temperature, and the energy efficiency of the DHS will be affected negatively in several ways (e.g., lower efficiency of the flue gas condenser, higher heat losses in pipes, and lower electricity production for a DHS with combined heat and power (CHP)). With a strategic introduction of low-grade heat customers, the return water temperature can be lowered and, to some extent, controlled. With the heat customers connected in parallel, which is the traditional setup, return water temperatures can only be lowered at the same rate as the heat customers are improved. The active management of some customers can lower the return water temperatures faster and, in the long run, lead to better controlled return water temperatures. Active management is defined here as an adjustment of a domestic heating system in order to improve DHS efficiency without affecting the heating service for the individual building. The opposite can be described as passive management, where heat customers are connected to the DHS in a standardized manner, without taking the overall DHS efficiency into consideration. The case study in this article shows possible efficiency gains for the examined DHS at around 7%. Looking at fuel use, there is a large reduction for oil, with 10-30% reduction depending on the case in question, while the reduction is shown to be largest for the case with the lowest return water temperature. The results also show that efficiency gains will increase electricity production by about 1-3%, and that greenhouse gas (GHG) emissions are reduced by 4-20%.

Place, publisher, year, edition, pages
MDPI , 2019. Vol. 12, no 10, article id 1863
Keywords [en]
district heating; system perspective; low-grade district heating; return water temperature
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:liu:diva-158821DOI: 10.3390/en12101863ISI: 000471016700042OAI: oai:DiVA.org:liu-158821DiVA, id: diva2:1337691
Note

Funding Agencies|Swedish District Heating Association; Fjarrsyn (district heating and cooling research programme)

Available from: 2019-07-16 Created: 2019-07-16 Last updated: 2019-11-07

Open Access in DiVA

fulltext(4717 kB)2 downloads
File information
File name FULLTEXT01.pdfFile size 4717 kBChecksum SHA-512
2d6e7da613c3a1887511557cb6320780efe85c97da9218928860715f5b9eb043eae00e3a228b41fcd3f04a66f29789b0624ce62a8ce03436fa1b3c99e3a082d1
Type fulltextMimetype application/pdf

Other links

Publisher's full text

Search in DiVA

By author/editor
Rosén, TommyÖdlund, Louise
By organisation
Energy SystemsFaculty of Science & Engineering
In the same journal
Energies
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 2 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 12 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf