En studie i vattenrening med elektrokoagulation: Koaguleringsförmågan hos utvalda föreningar
Karlstad University, Faculty of Health, Science and Technology (starting 2013), Department of Engineering and Chemical Sciences (from 2013).
2019 (Swedish)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesisAlternative title
A study of wastewater treatment using electrocoagulation : The coagulation capabilities of a selection of organic compounds (English)
Abstract [sv]

Vatten- och energiförbrukning är ett av mänsklighetens största nuvarande och framtida problem då världens vattenkonsumtion ständigt ökar på grund av bättre levnadsstandard samt ständigt ökande population och industrialisering. Förorenat vatten orsakar sjukdomar, sänkt livstid, reducerad sanitet och försämrad hälsa. Att rena vatten på ett energi- och miljöeffektivt sätt så att det kan återanvändas är därför ett måste för en hållbar framtid.

En undersökning av koaguleringsförmågan för ett antal utvalda organiska föreningar via elektrokoagulation har utförts hos företaget Axolot Solutions AB. Axolot Solutions AB är ett företag som arbetar med rening av industriella vatten med elektrokemiska metoder, framförallt elektrokoagulation. De organiska föreningar som undersökts har delats in i grupperna sockerarter (maltos, raffinos, glukos samt laktos), organiska syror (myrsyra, citronsyra, hexansyra, smörsyra, oktansyra), alkoholer (1-propanol, 2-propanol), fettsyror (lecitin) och övriga (formaldehyd, vanillin, nonylfenol, α-pinen). Även ett industriellt vatten från en barkavvattningsprocess har undersökts samt modellvatten av ämnena xylan och lignin som kan hittas i barkvatten.

Reningsförmågan av processen har undersökts genom att mäta COD halter före och efter behandling med ett kontinuerligt elektrokoagulationssystem. Varje förening har undersökts vid fyra olika initial pH: 4, 6, 7,5 och 9 och dessutom såväl järnanod och aluminiumanod testats. Även olika strömstyrkor har undersökts för ett par av de organiska föreningarna.

Resultaten visar ingen COD reduktion för vatten innehållande xylan, sockerarter, organiska syror och alkoholer. Tekniken visade mycket god reduktion av ämnena: lecitin (85,5%) och lignin (98,1%). En mindre reduktion skedde även för vatten innehållande nonylfenol (33,6%), α-pinen (42,1%), och barkvatten (21,5%). En reduktion av COD skedde även för vanillinvatten med initial pH 4 vid användandet av aluminiumanod, detta var dock det enda vattnet innehållande vanillin som påverkades. Det går inte att dra någon generell slutsats kring vilket initial pH och vilken anod som bör användas vid elektrokoagulation då den mest effektiva anordningen inte är densamma för de olika undersökta föreningarna.

Abstract [en]

Water- and energy consumption is one of humanities biggest current and future problems because of ever increasing global water consumption and because of better living conditions, increasing population and industrialization. Polluted water results in diseases, reduced life expectancy, sanitation and reduced overall health of those affected. Purifying water in an energy and environmentally effective way is therefore a must for a sustainable future.

A study of the coagulation capabilities for a select number of organic compounds by electrocoagulation has been performed at Axolot Solutions AB. Axolot Solutions AB is a company developing electrochemical water treatment solutions, with a focus on the electrocoagulation process. The compounds that have been studied are sugars (raffinose, maltose, glucose, lactose), organic acids (formic acid, citric acid, hexanoic acid, butyric acid, octanoic acid), alcohols (1-propanol, 2-propanol), fatty acids (lecithin), others (formaldehyde, vanillin, nonylphenol, α-pinene). Industrial water coming from a debarking process was also investigated as well as two compounds that are often present in this type of water, xylan and lignin.

The treatment efficiency was determined by measuring the COD values of the investigated water before and after the electrocoagulationprocess. Each compound was studied by using an iron anode and an aluminum anode at four different initial pH values: 4, 6, 7.5, 9. Different current densities were also studied for some of the investigated compounds.

The results show no COD reduction for sugars, alcohols, organic acids and xylan. The process resulted in large reductions of the compounds lecithin (85.5%) and lignin (98.1%). A lesser reduction was found for the waters containing: nonylphenol (33.6%), α-pinene (42.1%) and barkwater (21.5%). A reduction of COD was also found in the water containing vanillin with an initial pH of 4 that was treated with an aluminum anode was affected. The most efficient setup for the investigated compounds varies. For that reason, no conclusion as to which initial pH and anode that should be for electrocoagulation processes in general can be drawn.

Place, publisher, year, edition, pages
2019. , p. 73
Keywords [sv]
vattenrening, elektrokemi, elektrokoagulation, organiska föreningar
National Category
Water Treatment
Identifiers
URN: urn:nbn:se:kau:diva-73528OAI: oai:DiVA.org:kau-73528DiVA, id: diva2:1335876
External cooperation
Axolot Solutions AB
Educational program
Engineering: Energy and Environmental Engineering (300 ECTS credits)
Supervisors
Examiners
Available from: 2019-09-02 Created: 2019-07-08 Last updated: 2025-02-10Bibliographically approved

Open Access in DiVA

fulltext(10751 kB)880 downloads
File information
File name FULLTEXT01.pdfFile size 10751 kBChecksum SHA-512
e0d567065da79454adf745efd2c63ef7a7c56eadad055a5387368e89f048588219e654b82c86844cb46dc6d6748c3cb1434a2d5802a27fd13b09dd4bf72a671c
Type fulltextMimetype application/pdf

By organisation
Department of Engineering and Chemical Sciences (from 2013)
Water Treatment

Search outside of DiVA

GoogleGoogle Scholar
Total: 881 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 937 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf