Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Ljudreduktion i ventilationskanaler
KTH, School of Engineering Sciences (SCI).
KTH, School of Engineering Sciences (SCI).
2019 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Noise reduction in air ducts (English)
Abstract [sv]

Denna rapport för kandidatexamensarbete inom ljud och vibrationer riktar sig åt att undersöka beteendet av ljudreduktion för låga frekvenser och se när brytpunkten för så kallat breakout noise uppstår. Fokus ligger kring huruvida det finns en mättnad i ljudreduktion, enligt teori, på 6 dB per meter av ljuddämpare under 250 Hz. Ljuddämparen som används i projektet är CLA-A-250 från Swegon. Projektet kom till liv från företaget LN Akustikmiljö då de upplevde ett annat dämpningsbeteende än just det. Mätningarna för projektet tog plats i MWL-laboratoriet på KTH. Som kan åskådas i resultatet visar det sig att antagandet om 6 dB dämpning per meter av ljuddämpare är felaktigt. Gällande breakout noise så är det tydligt att så länge kanalstrukturen och dess utlopp är i skilda rum så är det inte ett problem. Dessa slutsater är säkra att göra på grund av användandet av standarder och marginaler som togs hänsyn till i beräkningar och mätningar. Projektet var en bra insikt i hur en period i yrkeslivet kan se ut för en akustiker.

Abstract [en]

The bachelor thesis report in the field of sound and vibrations aims to see the behaviour of sound reduction within low frequencies and see the tipping point for breakout noise, leakage of sound through the material. The focus is on whether or not there is saturation in noise reduction, coming from theory, of 6 dB per meter of silencer below 250 Hz. The silencer used in this project is the CLA-A-250 from Swegon. Measurements are made in the MWL laboratory at KTH. The project arose from the company LN Akustikmiljö as they experienced different behaviour during projects of their own. As can be seen in results, the saturation of 6 dB per meter of silencer does not apply and is not a correct assumption. Regarding the breakout noise, it is clear that as long as the duct structure and its outlet are in separate rooms it is not a problem. This conclusion is safe to make according to standards and the margins considered in the calculations.The project served as great insight in real life problems and applications of an acoustician.

Place, publisher, year, edition, pages
2019.
Series
TRITA-SCI-GRU ; 2019:184
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:kth:diva-254805OAI: oai:DiVA.org:kth-254805DiVA, id: diva2:1335459
External cooperation
LN Akustikmiljö
Supervisors
Examiners
Available from: 2019-07-05 Created: 2019-07-05 Last updated: 2019-07-05Bibliographically approved

Open Access in DiVA

fulltext(11061 kB)10 downloads
File information
File name FULLTEXT01.pdfFile size 11061 kBChecksum SHA-512
1c5b6ca4decab87db960a616ece051c0d232d907940e9aca16e2491dda6f00631b5a00a4c1b4abf735186490a268a50eccb6ecd4e91078ee12143a7eff807cba
Type fulltextMimetype application/pdf

By organisation
School of Engineering Sciences (SCI)
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 10 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 13 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf