Oxygenation conducted in low temperature clean water
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Engineering Sciences.
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Engineering Sciences.
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Engineering Sciences.
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Engineering Sciences.
Show others and affiliations
2019 (English)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [en]

Aeration tests were conducted under non-standard conditions with clean tap water in various temperatures below 20 °C, with the aim of studying changes that may occur. An initial deoxygenation of 0.8 litre water was performed with sodium sulfite and a cobalt catalyst pre-dissolved in water, in order to bind already present dissolved oxygen. The resulting dissolved oxygen concentration after 20 minutes did not decrease below 2 mg/L, despite increasing the sodium sulfite concentrations. Thereafter, a reoxygenation with the same time interval was conducted by using an aeration system, which resulted in an increase of saturated oxygen concentration with lower temperatures. pH-measurements were carried out during the whole experiment in order to follow the conversion of sulfite to sulfate. The pH-data obtained confirmed that sulfite had been converted to sulfate, although, a few deviations could be observed for most of the experiments. The conductivity was also measured to ensure that the sulfite had been properly dissolved when added to the water tank. In general, the conductivity never deviated and held a constant trend throughout the tests. The collected data could not be made of use in order to properly determine how the aeration, for temperatures below 20 °C, could be evaluated. Further tests have to be performed in order for a definite conclusion to be drawn.

Place, publisher, year, edition, pages
2019. , p. 32
Series
TVE-K ; 19006
National Category
Chemical Sciences
Identifiers
URN: urn:nbn:se:uu:diva-384153OAI: oai:DiVA.org:uu-384153DiVA, id: diva2:1335042
External cooperation
Xylem
Educational program
Master Programme in Chemical Engineering
Supervisors
Examiners
Available from: 2019-08-09 Created: 2019-07-03 Last updated: 2019-08-09Bibliographically approved

Open Access in DiVA

fulltext(1445 kB)508 downloads
File information
File name FULLTEXT02.pdfFile size 1445 kBChecksum SHA-512
7def99c0d64c9f367775c791b21aa3eee56a9b55eb6c21e923a4f8231cabe372284296256ee786920149446db4f930ee90b73899bde8c9fbaa0585b567a429aa
Type fulltextMimetype application/pdf

By organisation
Department of Engineering Sciences
Chemical Sciences

Search outside of DiVA

GoogleGoogle Scholar
Total: 508 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 463 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf