Beräkningsprogram för processpumpar inom skogsindustrin: Beräkningsprogram för att beräkna energieffektivitet och lönsamhet hos MC-pumpar och centrifugalpumpar vid installation av frekvensomriktare.
2019 (Swedish)Independent thesis Basic level (university diploma), 15 credits / 22,5 HE creditsStudent thesisAlternative title
Calculation software for process pumps in the forest industry : Calculation software for calculating the energy efficiency and the profitability of MCpumps and centrifugal pumps when installing a frequency converter. (English)
Abstract [sv]

I industrin finns det många pumpar som inte kör i de optimala driftfall som de är skapade för.

Detta bidrar till stora och onödiga kostnader för fabriker och industrier. Det finns olika

reglermetoder för att få pumpen att köra så optimalt som möjligt, det vanligaste är att avända

sig av en reglerventil som stryper bort flödet. Ett annat sätt är att investera i en

frekvensomriktare. En frekvensomriktare kan reglera varvtalet på pumpen och göra så driften

blir så optimal som möjligt för det driftfall som körs. Blir driften så optimal som möjligt

kommer kostnaden att reduceras. För att lätt kunna beräkna om det är lönsamt att investera i

en frekvensomriktare behövs ett standardiserat beräkningsprogram.

Detta arbete har gjorts för ÅF Pöyry i Karlstad i samverkan med BillerudKorsnäs AB,

Gruvön. Datainsamling har skett på BillerudKorsnäs AB på en MC-pump (423P008) denna

sitter på SK 2, som även kallas barrlinjen, där man behandlar barrträd.

Resultatet är ett standardiserat beräkningsprogram för att kunna beräkna både MC-pumpar

och centrifugalpumpar i pappersmassaindustrin. Detta beräkningsprogram kan bland annat

beräkna den totala tryckhöjden för respektive pump för att sedan kunna beräkna payoff-tiden,

alltså om det är lönsamt att investera i en frekvensomriktare.

Vid beräkning med hjälp av beräkningsprogrammet på MC-pump 423P008 visas det att ca

120 000 SEK/år är de kostnader som ”stryps” bort med den nuvarande reglermetoden, detta

är också den besparingspotetnial som kan göras vid investering av en frekvensomriktare och

detta är endast för en pump på ett bruk.

Slutsatsen man kan dra med hjälp av beräkningsprogrammet är att det finns stora kostnader

att spara i industrin genom att optimera drifterna hos de pumpar som finns.

Abstract [en]

In the industry, there are many pumps that do not running in the optimal operating conditions

that they are created for. This contributes to large, unnecessary costs for industries. There are

some different “control methods” to make the pump run as optimally as possible. One way is

to invest in a frequency converter. A frequency converter can regulate the speed (rpm) of the

pump and make the operation as optimal as possible for the running case. If the operation

becomes as optimal as possible, money will be saved. In order to easily calculate whether it is

profitable to invest in a frequency converter, a standardized calculation program is needed.

This work has been made for ÅF Pöyry in Karlstad in a collaboration with BillerudKorsnäs

AB, Gruvön. Data collection has taken place at BillerudKorsnäs AB on an MC-pump

(423P008), which is stationary at SK 2, which is also called the coniferous-line, where you

process conifers.

The result is a standardized calculation program for calculating both MC-pumps and

centrifugal pumps in the pulp industry. This calculation program can calculate the total pump

head for each pump in order to then calculate the payoff time, i.e. whether it is profitable to

invest in a frequency converter, or not.

When using the calculation program for the MC-pump named 423P008, it is shown that

about SEK 120,000 SEK / year are the costs that are "throttled" away with the current

“control method”. This is data for just one pump out at BillerudKorsnäs.

The conclusion is that with the help of the calculation program you can see there are large

costs to save in the industry by optimizing the runs of the pumps that are available.

Place, publisher, year, edition, pages
2019. , p. 55
Keywords [en]
MC-pump, centrifugal pump, frequency converter, calculation program, control valve, pressure drop, pump head, energy loss, payoff time, cost savings.
Keywords [sv]
MC-pump, centrifugalpump, frekvensomriktare, beräkningsprogram, reglerventil, tryckfall, tryckhöjd, energiförlust, payoff-tid, kostnadsbesparing.
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:kau:diva-72723OAI: oai:DiVA.org:kau-72723DiVA, id: diva2:1327005
External cooperation
ÅF Pöyry
Subject / course
Mechanical Engineering
Educational program
Study Programme in Mechanical Engineering
Supervisors
Examiners
Projects
NejAvailable from: 2019-06-20 Created: 2019-06-18 Last updated: 2019-06-20Bibliographically approved

Open Access in DiVA

fulltext(8877 kB)52 downloads
File information
File name FULLTEXT01.pdfFile size 8877 kBChecksum SHA-512
3ee134c31fcf05ef449d0945296fd35f7f95bd72b26a633729c411d10bcda8e98f78fd713f53fb10507950bfdd13b4e234ff1716f3dd65ad3b9dc803901a58cd
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Johansson, Ellen
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 52 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 75 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf