Design of an X-ray transfer beamline for the Soft X-ray project at MAX IV
2019 (English)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [en]

At the MAX-IV lab in Lund, there is a current goal to build a new soft X-Ray laser. The beam will be generated from a free-electron laser (FEL), which is an instrument consisting of high-speed electrons. The electrons move through alternating magnetic fields, causing the beam to become monochromatic. After the FEL, the Xrays will enter a beamline consisting of different optical components, such as mirrors, gratings and slits. This project investigated the necessary parameter values of the components, in order for the new X-Ray laser to focus the beam enough. The project consisted of a theoretical part and a simulation part. The use of so-called Kirkpatrick-Baez mirrors enables the beam to be very focused. The best focus achieved was 7.23um*10.87um for ''Pink beamline'' and the intensity at the end was 71.5%, which meant that only 30% of the rays were lost. For the monochromatic beamline, a loss of intensity is inevitable. With a pair of KBmirrors, this beam was focused to be 6.95um*9.80um. The energy spread is ranging from 6.198 eV to 0.3442 eV. The analytical calculations for the spot size matched well with the simulations. The pink beamline which was built in Ray satisfied the criterias of a spot size and intensity loss. The monochromatic beamline did fullfil the criterias of spot size and narrowing the energy spread. A loss of intensity will for this beamline be inevitable. Studying the misalignment effect showed that the components were most sensitive for vertical misalignment. The most sensitive parameters were the curvature of the mirrors.

Place, publisher, year, edition, pages
2019. , p. 41
Series
TVE-F ; 19003
Keywords [en]
optics, focusing, beam, x-ray, MAX-IV, soft x-ray, transfer, matrix
National Category
Atom and Molecular Physics and Optics
Identifiers
URN: urn:nbn:se:uu:diva-385901OAI: oai:DiVA.org:uu-385901DiVA, id: diva2:1326293
Educational program
Master Programme in Engineering Physics
Presentation
2019-06-04, Ångströmlaboratotiet, Lägerhyddsvägen 1, Uppsala, 15:00 (Swedish)
Supervisors
Examiners
Available from: 2019-06-24 Created: 2019-06-18 Last updated: 2019-06-24Bibliographically approved

Open Access in DiVA

Emadi_BeasPeterson_Tynelius_Ljung_kandidatarbete(1726 kB)25 downloads
File information
File name FULLTEXT01.pdfFile size 1726 kBChecksum SHA-512
40ee5318d84a2685473f974b5cbcb352efe71ff81141c55ef92a7433977382001c68c53832c4f4736bbbd6b80ca6fc15f031f60ad3d4a51a629a1c0968866d5e
Type fulltextMimetype application/pdf

Atom and Molecular Physics and Optics

Search outside of DiVA

GoogleGoogle Scholar
Total: 25 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 38 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf