Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Sensorbaserad skosula: Utveckling av prototyp för uppföljning efter behandling av idiopatisk tågång
KTH, School of Engineering Sciences in Chemistry, Biotechnology and Health (CBH), Biomedical Engineering and Health Systems, Health Informatics and Logistics.
KTH, School of Engineering Sciences in Chemistry, Biotechnology and Health (CBH), Biomedical Engineering and Health Systems, Health Informatics and Logistics.
2019 (Swedish)Independent thesis Basic level (university diploma), 10 credits / 15 HE creditsStudent thesisAlternative title
Sensor-based insole : Development of prototype for evaluation of post treatment for idiopathic toe walking (English)
Abstract [sv]

Denna rapport behandlar konstruktionen av en sensorbaserad skosula. Skosulan designades med en mängd trycksensorer som sedan visualiseras på en mobilapplikation. Mobilapplikationen anslöts till sulan via Bluetooth. Det är vanligt att majoriteten av små barn går på tå. Ifall barnet inte slutar gå på tå efter barnet fyllt 2–3 år bör man kontakta läkare. Det finns olika teorier angående vilken typ av behandling som är bäst för barnen. I dagsläget finns det ingen bra lösning för att följa upp behandlingarna på barnen. Prototypen är designad för att uppfylla de krav som behövs för att ge en bra bedömning ifall behandlingen som barnet fått förbättrat barnets belastning på foten. Rapporten går även in på andra användningsområden som sulan skulle kunna användas inom. Slutsatsen i rapporten är att utveckling av produkten är möjlig men kräver mer forskning inom området samt vidareutveckling av prototypen. Prototypen är i för tidigt stadie för att utföra riktiga tester på en försöksgrupp. För att validera sensorernas precision bör lämpliga testfall utvecklas.

Abstract [en]

This report goes through the development of a sensor-based insole. The insole was designed with multiple pressure sensors which are then visualized on a mobile application. The mobile application was connected to the insole via Bluetooth. It is common for toddlers to prefer toe walking. If the child does not stop toe walking after the age of 2-3 years, you should contact a doctor. There are different kinds of treatment for these children. Today there isn’t a good solution to evaluate the children post treatment. The prototype is designed to meet the requirements needed to give a good assessment of whether the child has improved or not. The report also addresses other use cases for the insole. The conclusion on the report is that development of the product is possible but requires more research in the field as well as further development of the prototype. The prototype is in a too early stage to perform true tests on a trial group. To validate the sensor's precision, appropriate test cases should be developed. 

Place, publisher, year, edition, pages
2019. , p. 46
Series
TRITA-CBH-GRU ; 2019-038
Keywords [en]
Piezoelement, microcontroller, bluetooth low energy, idiopathic toe walking.
Keywords [sv]
Piezoelement, mikrokontroller, bluetooth low energy, idiopatisk tågång.
National Category
Embedded Systems
Identifiers
URN: urn:nbn:se:kth:diva-253059OAI: oai:DiVA.org:kth-253059DiVA, id: diva2:1323922
Subject / course
Electrical Engineering
Educational program
Bachelor of Science in Engineering - Electrical Engineering
Supervisors
Examiners
Available from: 2019-06-13 Created: 2019-06-12 Last updated: 2019-06-13Bibliographically approved

Open Access in DiVA

Console(2816 kB)19 downloads
File information
File name FULLTEXT01.pdfFile size 2816 kBChecksum SHA-512
91e841becee5a775a63328ca02c424260b204158355046537ebbd9150128a6d88be8f3c1c779fa5fca6d562dc0c949437957b72e2b184fbb5a2065941d502b90
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Liljedahl, HampusPersson, Arvid
By organisation
Health Informatics and Logistics
Embedded Systems

Search outside of DiVA

GoogleGoogle Scholar
Total: 19 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 106 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf