Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Fjärrvärme och frånluftsvärmepump: Systemets lönsamhet och primärenergitalets inverkan
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science, Energy Systems and Building Technology.
2019 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Kombinationen av fjärrvärme och frånluftsvärmepump (FVP) har blivit allt vanligare i Sverige. Detta kombinerade värmesystem är väl lämpat för att reducera energianvändningen i befintliga fastigheter med mekanisk frånluftventilation som saknar värmeåtervinning. Dock kan en FVP-installation leda till högre returtemperaturer i fjärrvärmenätet vilket det ofta finns avgifter för i dagsläget. För att främja fjärrvärmeanvändning sommartid använder fjärrvärmeleverantören sig av säsongsvarierande prismodeller i vilket fjärrvärmepriset varierar under en del av året. Genom att stänga av FVP sommartid och endast bruka fjärrvärme finns en potentiell kostnadsbesparing då fjärrvärmepriset är som lägst. Denna kostnadsbesparing undersöks utifrån olika typer av fjärrvärmetaxor, elnätsavgifter och elhandelspris. Det undersöks också hur Boverkets regler för beräkning av primärenergital påverkar denna värmesystemtyp. Typiska prismodeller för fjärrvärme har undersökts, samt så har energianvändning framräknats för sex fiktiva flerbostadshus runtom i landet. För varje byggnad beräknas energianvändningen utifrån tre fall. I referensfallet, Fall 1 används bara fjärrvärme och i Fall 2 används FVP till både uppvärmning och tappvarmvatten (TVV). Fall 3 är som Fall 2 fast FVP täcker inget TVV-behov och stängs av under sommar-perioden. Energianvändningen är framräknad över ett år och energikostnaden jämförs mellan fallen. I Fall 2 och Fall 3 är de totala energikostnaderna för byggnaderna mellan 61–75% respektive 67–78% av energikostnaderna i Fall 1. Mellan Fall 2- och 3 finns däremot ingen tydlig besparingstrend trots att alla fjärrvärmenät på orterna har ett säsongsvarierande fjärrvärmepris. Att ingen besparingstrend uppstår påvisar att kostnaden för varje levererad värmeenhet från FVP sommartid är ungefär lika stor som varje värmeenhet fjärrvärme. Detta beror på att en hög värmefaktor används vilket gör det väldigt kostnadseffektivt att köpa el. Med en lägre värmefaktor gynnas avstängning av FVP sommartid. Utifrån den framräknade energianvändningen beräknas primärenergitalet och den specifika energianvändningen för samtliga byggnader. Primärenergitalet är i de flesta fall större än den specifika energianvändningen för att elanvändningen räknas upp. I Luleå är däremot den specifika energianvändningen större än primärenergitalet, även vid användning av FVP.

Abstract [en]

The combination of district heating and exhaust air heat pump (EAHP) has become increasingly common in Sweden. This combined heating system is well suited for reducing energy use in existing buildings with mechanical exhaust air ventilation that lacks heat recovery. However, an EAHP installation can lead to higher return temperatures in the district heating network. In order to promote district heating use during the summer, the district heating supplier use seasonal varying price models in which the district heating price varies during some of the year. By shutting down EAHP in summer and only using district heating, there is a potential cost saving as the district heating price is at its lowest. This cost saving is investigated based on various types of district heating tariffs, electricity grid charges and electricity prices. It is also examined how Boverket's rules for calculating primary energy affects this type of heating system. Typical price models for district heating have been investigated. The energy use for six fictitious multi-dwelling buildings around the country has also been made. For each building, the energy use was calculated from three cases. For the reference case, Case 1, only district heating is used, for Case 2 EAHP is used for both heating and domestic hot water and Case 3 is as Case 2 fixed EAHP does not cover domestic hot water requirements and is switched off during the summer period. The energy consumption is calculated over a year and the energy cost is compared between the cases. In Case 2 and Case 3, the total energy costs for the buildings are between 61–75% and 67–78% of the energy costs in Case 1, respectively. However, between Case 2- and 3, there is no clear saving trend despite all the locations having a seasonally varying district heating price. The fact that no saving trend arises shows that the cost of each heat unit delivered from FVP in the summer is about the same as each heating unit of district heating. This is because a high COP (coefficient of performance) is used, which makes it very cost-effective to buy electricity. With a lower COP, shutdown of EAHP benefits summer time. Based on the calculated energy use, the primary energy and the specific energy use are calculated for all buildings. In most cases, the primary energy number is larger than the specific energy use, as the electricity consumption is going to be larger with primary energy. In Luleå, on the other hand, the energy-area ratio is greater than the primary energy number, even when using an EAHP.

Place, publisher, year, edition, pages
2019. , p. 42
Keywords [en]
district heating, district heating tariff, exhaust air heat pump, combined heating system, cost efficiency, primary energy, primary energy factor
Keywords [sv]
fjärrvärme, fjärrvärmetaxa, frånluftsvärmepump, kombinerad värmeanläggning, kostnadseffektivisering, primärenergi, primärenergifaktor
National Category
Energy Systems
Identifiers
URN: urn:nbn:se:hig:diva-29713OAI: oai:DiVA.org:hig-29713DiVA, id: diva2:1321460
External cooperation
Greencon energi och miljö AB
Subject / course
Energy systems
Educational program
Högskoleingenjör
Presentation
2019-06-04, 91:204, Kungsbäcksvägen 47, Gävle, 13:30 (Swedish)
Supervisors
Examiners
Available from: 2019-06-11 Created: 2019-06-08 Last updated: 2019-06-11Bibliographically approved

Open Access in DiVA

fulltext(1158 kB)21 downloads
File information
File name FULLTEXT01.pdfFile size 1158 kBChecksum SHA-512
4c7217b4fece69d1ce89a733e6e604639f0a02f3b1f5b44607bda10d44812d41dcef19a77407bc0239ee2521ff0c7bfbbfabdb7d34b5bdfb1ad2fb4d79d1851e
Type fulltextMimetype application/pdf

By organisation
Energy Systems and Building Technology
Energy Systems

Search outside of DiVA

GoogleGoogle Scholar
Total: 21 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 253 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf