Making grid capacity available through heat pump control
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Engineering Sciences.
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Engineering Sciences.
2019 (English)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [en]

In this report the problem of constructing a bus depot with electrical buses despite the lack of grid capacity, was analyzed. A potential solution is investigated, namely smart control of heat pumps in industries. The possibility of allocating grid capacity to the bus depot by reducing power consumption in heat pumps during peak hours, is taken into consideration. The maximum amount of released capacity in an industrial area is calculated through the controlling of heat pumps. This investigation was made through simulations with a simplified building energy model (lumped capacity model) which was applied to a reference building.

After mapping the area Boländerna and the geothermal wells located there, IKEA Uppsala was chosen as the reference building, since a third of the total number of wells were found in that area. To take the whole capacity of Boländerna into account, the model was scaled up to estimate the total, possible reduction of power. The bus depot requires 6 MW nighttime and 4 MW daytime, the total amount of electrical power that could be withdrawn, if all heat pumps were on maximum heat, in the chosen area were 0.75 MW and by controlling the heat pumps during an optimized level, the amount of 142 kW could be made available to the electric grid. 142 kW is not enough cover the need for the bus depot but it could supply the need for a slow charger to one of the buses and is therefore a possible sub-solution to the larger problem.

Place, publisher, year, edition, pages
2019. , p. 34
Series
TVE-STS ; 19005
Keywords [en]
Grid, capacity, electricity, Uppsala, IKEA, peak shaving, electric bus, bus depot, lumped capacity model, Region Uppsala
National Category
Energy Systems
Identifiers
URN: urn:nbn:se:uu:diva-384182OAI: oai:DiVA.org:uu-384182DiVA, id: diva2:1319211
External cooperation
Region Uppsala
Educational program
Systems in Technology and Society Programme
Supervisors
Examiners
Available from: 2019-06-10 Created: 2019-05-30 Last updated: 2019-06-10Bibliographically approved

Open Access in DiVA

fulltext(1132 kB)14 downloads
File information
File name FULLTEXT01.pdfFile size 1132 kBChecksum SHA-512
cd649487e582d4702ef9bf8e2baf018127ce43abf71a5cb0d0f6092bb2960a4ee16a6ce77ac6a504b539bf8dc72097c1182319d51af75ce0f2b832380f288672
Type fulltextMimetype application/pdf

By organisation
Department of Engineering Sciences
Energy Systems

Search outside of DiVA

GoogleGoogle Scholar
Total: 14 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 98 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf