Digitala Vetenskapliga Arkivet

Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Needle Navigation for Image Guided Brachytherapy of Gynecologic Cancer
KTH, School of Engineering Sciences in Chemistry, Biotechnology and Health (CBH).
2019 (English)Independent thesis Advanced level (degree of Master (Two Years)), 80 credits / 120 HE creditsStudent thesisAlternative title
Navigering av nål vid bildstyrd brachyterapi av gynekologisk cancer (Swedish)
Abstract [en]

In the past twenty years, the combination of the advances in medical imaging technologies and therapeutic methods had a great impact in developing minimally invasive interventional procedures. Although the use of medical imaging for the surgery and therapy guidance dates back to the early days of x-ray discovery, there is an increasing evidence in using the new imaging modalities such as computed tomography (CT), magnetic reso- nance imaging (MRI) and ultrasound in the operating rooms. The focus of this thesis is on developing image-guided interventional methods and techniques to support the radiation therapy treatment of gynecologic cancers. Gynecologic cancers which involves malignan- cies of the uterus, cervix, vagina and the ovaries are one of the top causes of mortality and morbidity among the women in U.S. and worldwide. The common treatment plan for radiation therapy of gynecologic cancers is chemotherapy and external beam radiation therapy followed by brachytherapy. Gynecological brachytherapy involves placement of interstitial catheters in and around the tumor area, often with the aid of an applicator. The goal is to create an optimal brachytherapy treatment plan that leads to maximal radiation dose to the cancerous tissue and minimal destructive radiation to the organs at risk. The accuracy of the catheter placement has a leading effect in the success of the treatment.

However there are several techniques are developed for navigation of catheters and needles for procedures such as prostate biopsy, brain biopsy, and cardiac ablation, it is obviously lacking for gynecologic brachytherapy procedures.

This thesis proposes a technique which aims to increase the accuracy and efficiency of catheter placements in gynecologic brachytherapy by guiding the catheters with an electromagnetic tracking system. To increase the accuracy of needle placement a navigation system has been set up and the appropriate software tools were developed and released for the public use as a module in the open-source 3D Slicer software. The developed technology can be translated from benchmark to the bedside to offer the potential benefit of maximizing tumor coverage during catheter placement while avoiding damage to the adjacent organs including bladder, rectum and bowel. To test the designed system two independent experiments were designed and performed on a phantom model in order to evaluate the targeting accuracy of the tracking system and the mean targeting error over all experiments was less than 2.9 mm, which can be compared to the targeting errors in the available commercial clinical navigation systems.

Place, publisher, year, edition, pages
2019.
Series
TRITA-CBH-GRU ; 2019:014
Keywords [en]
Image Guided Surgery, Surgical Navigation System, Needle Navigation system, Brachytherapy, MRI, 3D Slicer
National Category
Medical Imaging
Identifiers
URN: urn:nbn:se:kth:diva-248042OAI: oai:DiVA.org:kth-248042DiVA, id: diva2:1301796
Subject / course
Medical Imaging
Educational program
Master of Science - Medical Engineering
Presentation
2014-06-10, 21:59 (English)
Supervisors
Examiners
Available from: 2019-09-06 Created: 2019-04-02 Last updated: 2025-02-09Bibliographically approved

Open Access in DiVA

fulltext(8122 kB)785 downloads
File information
File name FULLTEXT01.pdfFile size 8122 kBChecksum SHA-512
35ab9d82cbdff229f7f10e56418b5540cf0091bda4d46adb501e567f1e633275ea763f31890c38dcbe426ecd7e8243b68a773bacd4804f62fbd97159bb178329
Type fulltextMimetype application/pdf

By organisation
School of Engineering Sciences in Chemistry, Biotechnology and Health (CBH)
Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
Total: 785 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 459 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf