MULTI-CENTER QUANTITATIVE MEASUREMENT OF T1 ANDT2 RELAXATION TIMES IN THE RAT BRAIN
KTH, School of Engineering Sciences in Chemistry, Biotechnology and Health (CBH).
2018 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesisAlternative title
Multicenter-kvantitativa T1 och T2 relaxationstidsmätningar i smådjurshjärna (Swedish)
Abstract [en]

This project revolves around the measurement of T1 and T2 relaxation times in the ratbrain, in a multi-center way. That is to say, elaborate an efficient protocol to calculate highresolution 3D map of the brain. This protocol should be applied in different centers andreturn similar results. Finally, procedures should be defined to ease the collaborationbetween the different centers. The first step consisted in in vitro experiments, in whichdifferent sequences were tested. It resulted that the MDEFT sequence with inversionpreparation (MPRAGE) gives the best results in the shortest time for T1. For T2, theMSME sequence was chosen. The next step moved on in vivo experiments on three rats inorder to get used to manipulating living animals and make new adjustments. As thephysiology is not the same on in vitro and in vivo experiments, some parameters had to beslightly adapted. Once the final 2h-protocol was established, it was tested on a populationof ten rats. Experiments were made at the GIN and CRMBM. Different fitting pipelineswere tried (GIN, CRMBM, MIRCEN). The brain was segmented into different regions. Itresulted that the GIN and CRMBM pipelines return the same T1 values using the differentdatasets. The MIRCEN pipeline under-estimates by 200 ms. The three pipelines return similar T2 values. The GIN and CRMBM datasets provide comparable T1 values, but theGIN center presents slightly higher T2 values. Regarding the multi-center collaboration,the different pipelines were ported to the VIP platform so that the scientific community caneasily reuse them.

Place, publisher, year, edition, pages
2018. , p. 90
Series
TRITA-CBH-GRU ; 2018:73
Keywords [en]
MRI; Relaxation Times; T1; T2; Rat; Brain; Quantitative; Multi-center
National Category
Medical Engineering
Identifiers
URN: urn:nbn:se:kth:diva-232040OAI: oai:DiVA.org:kth-232040DiVA, id: diva2:1231794
External cooperation
Grenoble Institute of Neurosciences - 31 Chemin Fortuné Ferrini, 38700 La Tronche, France
Subject / course
Medical Engineering
Educational program
Master of Science - Medical Engineering
Supervisors
Examiners
Available from: 2018-07-19 Created: 2018-07-09 Last updated: 2018-07-19Bibliographically approved

Open Access in DiVA

DERUELLE_STUDENT_THESIS(4070 kB)7 downloads
File information
File name FULLTEXT01.pdfFile size 4070 kBChecksum SHA-512
42370bd181dba600026a8d84ff7917926f3bea0ee75cceb4aa11b928de664d889091e6d65d207dd1ac587b838d52c0b60dd01cde79bad03e24180c59bb30e451
Type fulltextMimetype application/pdf

By organisation
School of Engineering Sciences in Chemistry, Biotechnology and Health (CBH)
Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 7 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 17 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf