Energiuppföljning på ett modernt sjukhus: En analys av förvaltningsmodellen på Nya Karolinska Solna
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Engineering Sciences, Solid State Physics.
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Engineering Sciences, Solid State Physics.
2018 (Swedish)Independent thesis Advanced level (professional degree), 20 credits / 30 HE creditsStudent thesisAlternative title
Energy follow-up on a modern hospital : An analysis of the energy model at Nya Karolinska Solna (English)
Abstract [en]

The purpose of this study was to develop an operation method to manage the energy model at Nya Karolinska Solna and apply it to a fully operational floor in the facility. Deficiencies and improvement potential was then analysed for future management of the model.

Manual measurements were performed on the examined floor regarding heating, cooling and facility electricity and were then compared to the corresponding parameters calculated by the model. The model was calibrated with actual airflows, time schedules and internal gains to get a representative comparison with the measured energy use.

The results show that the developed mode of operation works well for the examined floor but has some improvement areas for when it should be applied to the the entire facility as a lot of processes connected to updating the model are time consuming. Improvement potential was found concerning the acquisition of data and calibration of the model. The proposed mode of operation could be improved by firstly concluding the actual usage of the occupants to adjust air flows, time schedules and internal gains and secondly, by implementing a system of reporting future deviations from normal operational patterns.

The total actual energy use compares well to the energy use calculated by the model. However, if comparing the parameters individually, deviation is evident. It was also found that values in the model for internal gains are overestimated during days and underestimated during nights and weekends resulting in a deviation of the compared parameters of the examined floor.

Place, publisher, year, edition, pages
2018. , p. 78
Series
UPTEC STS, ISSN 1650-8319 ; 18031
Keywords [sv]
Energiuppföljning, energiprestanda, energiberäkningsmodell, sjukhus
National Category
Environmental Analysis and Construction Information Technology
Identifiers
URN: urn:nbn:se:uu:diva-355849OAI: oai:DiVA.org:uu-355849DiVA, id: diva2:1231227
External cooperation
Coor
Educational program
Systems in Technology and Society Programme
Supervisors
Examiners
Available from: 2018-07-06 Created: 2018-07-05 Last updated: 2018-07-06Bibliographically approved

Open Access in DiVA

fulltext(3170 kB)2 downloads
File information
File name FULLTEXT01.pdfFile size 3170 kBChecksum SHA-512
acaafad1720b32c861a1ffa16d3d4d7783d8928f2befefa46f599c1ef777931cb51274610b780d8af3ed5c126079d7028c92b0935d70e18c1c36a4f1f6ef6c77
Type fulltextMimetype application/pdf

By organisation
Solid State Physics
Environmental Analysis and Construction Information Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 2 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 6 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf