Energieffektivisering av miljonprogrammet i samband med våningspåbyggnad: Energisimulering i IDA ICE
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Building Technology and Design.
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Building Technology and Design.
2018 (Swedish)Independent thesis Basic level (university diploma), 10 credits / 15 HE creditsStudent thesisAlternative title
Energy efficiency of the milion program in conjuction with story extension : Energy simulation usin IDA ICE (English)
Abstract [sv]

En stor del av alla bostäder som byggdes mellan 1965-1974 brukar betecknas miljonprogrammet. Efter 40-50 års förbrukning har byggnaderna uppnått sin tekniska livslängd och är därför i behov av renovering. Detta samtidigt som bostadsbristen återstår och energikraven från myndigheter blir allt strängare i syfte att reducera bostadssektorns energianvändning samt för att uppnå ett hållbart samhälle. 

Studien är baserad på ett flerbostadshus, Barytongatan 4 som är belägen i Göteborg och som är en del av projektet Kaverös etapp II. I denna studie undersöks energibesparingsåtgärder i samband med våningspåbyggnad och de regelverk som gäller vid om- och tillbyggnad enligt BBR och PBL. I simuleringsprogrammet IDA ICE kunde olika energibesparingsåtgärder studeras. Resultatet från varje enskild åtgärd och en sammansättning av dessa jämfördes därefter med den befintliga byggnadens energideklaration och statisk. Studien är koncentrerad till energisimuleringar och behandlar inga ekonomiska beräkningar.

Rapporten fastställer att en våningspåbyggnad, som ökar byggnadsvolymen, är en tillbyggnad samt att allt för stora åtgärder i en befintlig byggnad klassas som en ombyggnad enligt BBR och PBL. Studien berör energibesparingsåtgärder gällande FX-system, FTX-system, balkonginglasning och solpaneler på tak. Resultatet visar att med endast få ingrepp i referenshuset, i enlighet med regelverken, kunde energianvändningen reduceras från 147 kWh/m² till 104,8 kWh/m², vilket motsvarar 28,8 procent.

Abstract [en]

A majority of houses that were built during the years 1965-1974 is usually referred to as the million program. After 40-50 years of use, the buildings have reached their technical life expectancy and need to be renovated. At the same time, the lack of housing shortage continues to exist while energy requirements from the government are becoming increasingly strict. The government maintains and run a strict policy to reduce the energy consumption of the housing sector in hope of achieving a more sustainable society.

The study is based on a multi-family house located in Kaverös, Gothenburg at Barytongatan 4, which is part of the Kaverös Stage II project. In this study, energy conservation measures are investigated in connection with story extension and the applicable regulations when it comes to rebuilding and upgrading in accordance with BBR and PBL.

Using the IDA ICE simulation program, different energy conservation measures could be studied. The result of each individual energy conservation measure, and a combination of these were then compared with the existing building's energy declaration and static. This study is limited to energy calculation and no financial calculations are presented

The result shows that only a few interventions in the reference housing, according to the regulations BBR and PBL, can affect the energy consumption and reduce it from 147 kWh/m² to 104.8 kWh/m², which corresponds to 28.8 percent.

Place, publisher, year, edition, pages
2018. , p. 80
Series
TRITA-ABE-MBT ; 1869
Keywords [en]
BBR, PBL, IDA ICE, energy, FTX-system, FX-system, solar panels, renovation, story extension, extension, reconstruction, million program, energy, energy requirements, energy performance, energy saving measures
Keywords [sv]
BBR, PBL, IDA ICE, energy, FTX-system, FX-system, solar panels, renovation, story extension, extension, reconstruction, million program, energy, energy requirements, energy performance, energy saving measures
National Category
Building Technologies
Identifiers
URN: urn:nbn:se:kth:diva-231549OAI: oai:DiVA.org:kth-231549DiVA, id: diva2:1229300
External cooperation
COWI AB
Subject / course
Building Technology
Educational program
Bachelor of Science in Engineering - Constructional Engineering and Design
Supervisors
Examiners
Available from: 2018-07-03 Created: 2018-06-29 Last updated: 2018-07-03Bibliographically approved

Open Access in DiVA

fulltext(9781 kB)21 downloads
File information
File name FULLTEXT01.pdfFile size 9781 kBChecksum SHA-512
b6d4e6755402f67ef73454924de8105ec2cbc851d06f02e86a487365f874b3b12c3f82bde3d15aa77e4dbc6ee4ae6a466a0b5e414745641d95f891a25920945c
Type fulltextMimetype application/pdf

By organisation
Building Technology and Design
Building Technologies

Search outside of DiVA

GoogleGoogle Scholar
Total: 21 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 60 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf