Evaluation of a Centralized Substation Protection and Control System for HV/MV Substation
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Engineering Sciences, Electricity.
2018 (English)Independent thesis Advanced level (professional degree), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

Today, conventional substation protection and control systems are of a widely distributed character. One substation can easily have as many as 50 data processing points that all perform similar algorithms on voltage and current data. There is also only limited communication between protection devices, and each device is only aware of the bay in which it is installed. With the intent of implementing a substation protection system that is simpler, more efficient and better suited for future challenges, Ellevio AB implemented a centralized system in a primary substation in 2015. It is comprised of five components that each handle one type of duty: Data processing, communication, voltage measurements, current measurements and breaker control. Since its implementation, the centralized system has been in parallel operation with the conventional, meaning that it performs station wide data acquisition, processing and communication, but is unable to trip the station breakers. The only active functionality of the centralized system is the voltage regulation. This work is an evaluation of the centralized system and studies its protection functionality, voltage regulation, fault response and output signal correlation with the conventional system. It was found that the centralized system required the implementation of a differential protection function and protection of the capacitor banks and busbar coupling to provide protection equivalent to that of the conventional system. The voltage regulation showed unsatisfactory long regulation time lengths, which could have been a result of low time resolution. The fault response and signal correlation were deemed satisfactory.

Place, publisher, year, edition, pages
2018. , p. 79
Series
UPTEC F, ISSN 1401-5757 ; 18026
Keywords [en]
Substation system architecture, Centralized Protection and Control, Voltage regulation
National Category
Computer Systems
Identifiers
URN: urn:nbn:se:uu:diva-354976OAI: oai:DiVA.org:uu-354976DiVA, id: diva2:1223283
External cooperation
Ellevio AB
Educational program
Master Programme in Engineering Physics
Supervisors
Examiners
Available from: 2018-06-26 Created: 2018-06-25 Last updated: 2018-06-26Bibliographically approved

Open Access in DiVA

fulltext(6245 kB)10 downloads
File information
File name FULLTEXT01.pdfFile size 6245 kBChecksum SHA-512
3886423715d13c1fcca83260201a40be6723a650b98fea47ef59d7d5f8de57bc80c83dd389572ffc15d6c72eae0b437d64ba570901c6bc81be278b559071ad74
Type fulltextMimetype application/pdf

By organisation
Electricity
Computer Systems

Search outside of DiVA

GoogleGoogle Scholar
Total: 10 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 27 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf