Thermo-mechanical analysis of cryo-cooled electrode system in COMSOL
Uppsala University, Disciplinary Domain of Science and Technology, Physics, Department of Physics and Astronomy.
2018 (English)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [en]

In the planned linear accelerator called Compact Linear Collider, CLIC, electrons and positrons will be accelerated to velocities near the speed of light. A limiting factor in accelerating structures are vacuum breakdowns, which are electrical discharges from a surface as a result of a large electric field being applied. In the preparatory studies for the CLIC, Uppsala University in collaboration with The European Organization for Nuclear Research, CERN, is building a DC Spark system to analyze vacuum breakdowns. This system containing large planar electrodes will be cooled down all the way down to around 4 K in order to limit the rate of wich vacuum breakdowns happen. When cooling a system like this, which consists of different components made of different materials there is the question of how the system will be affected. The objective of this project is to investigate how the cooling will affect the stability in terms of stresses and to analyze the cool down time of the system. Another goal is to make a material recommendation for a few parts based on the results. This will be done by simulating the cooling in COMSOL Multiphysics, which is a program that uses finite element analysis to solve complex problems where different branches of physics interact. The conclusion is that the system will most likely be stable as it is and there is no need to redesign it. The choice of recommended material is alumina with the reason being it should cause the least stress and the smallest gap between the electrodes when the cooling is done. There was no big difference in the cool down time between the materials. Further studies and simulations on the system is also recommended since there are many factors not taken into consideration in this study.

Place, publisher, year, edition, pages
2018.
Series
TVE-F ; 18 015
Keywords [en]
accelerator, compact linear collider, clic, cern, vacuum breakdowns, breakdowns, comsol, cryo-cooled, cryogenics, cryocooler, DC spark, electrode system
National Category
Accelerator Physics and Instrumentation
Identifiers
URN: urn:nbn:se:uu:diva-353895OAI: oai:DiVA.org:uu-353895DiVA, id: diva2:1219711
Educational program
Master Programme in Engineering Physics
Supervisors
Examiners
Available from: 2018-06-20 Created: 2018-06-17 Last updated: 2018-06-20Bibliographically approved

Open Access in DiVA

Thermo-mechanical analysis of cryo-cooled electrode system in COMSOL(1778 kB)6 downloads
File information
File name FULLTEXT01.pdfFile size 1778 kBChecksum SHA-512
6f113238108ea7228b7402a7147bd207a79c19f2161bf38523740d2858160f3752bc1ff2112ca21c70fb4edbe0051abd5a7905645518944fb7b363c03ee20662
Type fulltextMimetype application/pdf

By organisation
Department of Physics and Astronomy
Accelerator Physics and Instrumentation

Search outside of DiVA

GoogleGoogle Scholar
Total: 6 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 17 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf