Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Fyllnadsnivåers påverkan, tidsförlängning innan analys och blodprovers stabilitet
Jönköping University, School of Health and Welfare, HHJ, Dep. of Natural Science and Biomedicine.
Jönköping University, School of Health and Welfare, HHJ, Dep. of Natural Science and Biomedicine.
2018 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
The Impact of Lower Sample Volumes, Pre-analytical Delay and Blood Sample Stability (English)
Abstract [sv]

Bakgrund: Provmaterial för joniserat kalcium är känsligt för pH-förändringar och med tanke på svårstuckna patienter är det betydelsefullt att undersöka lägre fyllnadsnivåers påverkan på analysresultatet. På grund av olika pre-analytiska faktorer kan tidsgränsen (4 timmar) för analys av standardbikarbonat överskridas. Förvaring av post-analytiska serumprover medför att kompletteringsanalyser kan beställas. Begränsad dokumentation finns om avkorkade serumprovers stabilitet i rumstemperatur. Syfte: Syftet var att undersöka hur lägre fyllnadsnivåer av serum påverkar analysresultatet för joniserat kalcium, om standardbikarbonatsprover på helblod kan analyseras senare än 4 timmar och hur länge serumprover kan stå i rumstemperatur utan kork för eventuella kompletteringsanalyser. Metod: Koncentrationen av analyten joniserat kalcium i serumprover med fyllnadsnivåerna 1 mL och 2 mL jämfördes med maximalt fyllda provrör. Kylskåpsförvarade helblodsprover analyserades för standardbikarbonat efter 4-7 timmar. Avkorkade serumprover analyserades för 10 biokemiska analyter efter att ha stått i rumstemperatur 2-8 timmar. Genomsnittlig procentuell avvikelse jämfördes med en analytisk och biologisk imprecisionsgräns för att bedöma analyters stabilitet. Resultat och slutsatser: Analysresultat av joniserat kalcium i lägre fyllnadsnivåer var tillförlitliga. Stabiliteten av standardbikarbonatsproverna kunde inte bedömas och därmed kunde inte en eventuell tidsgränsändring rekommenderas. De biokemiska analyterna var stabila upp till 8 timmar i rumstemperatur.

Abstract [en]

Background: Ionized calcium concentrations decrease when samples are exposed to air. Due to pre-analytical factors, the 4 hour time limit for analysis of standard bicarbonate, can sometimes be exceeded. There is limited documentation about additional analyses on post-analytic decapped serum samples stored at room temperature. Aim: The aim was to examine how lower sample volumes affect the concentration of ionized calcium, if the time limit for analysis of standard bicarbonate on whole blood can be prolonged and how long decapped serum samples can be stored at room temperature for eventual additional analyses. Methods: The concentration of ionized calcium was analyzed on serum samples filled with 1 mL and 2 mL and were compared to maximally filled samples. Refrigerated whole blood samples were analyzed for standard bicarbonate after 4-7 hours. Ten biochemical analytes were measured in decapped serum samples after 2-8 hours of storage at room temperature. The mean percentage deviation was compared to an analytical and biological imprecision limit to determine analyte stability. Results and conclusions: Ionized calcium concentrations in lower sample volumes were reliable. The stability of standard bicarbonate could not be determined, therefore a longer possible time limit could not be recommended. The biochemical analytes were stable for 8 hours.

Place, publisher, year, edition, pages
2018. , p. 22
Keywords [en]
Pre-analytical factors, Ionized calcium, Standard bicarbonate, Clinical chemistry tests, Post-analytical stability
Keywords [sv]
Pre-analytiska faktorer, Joniserat kalcium, Standardbikarbonat, Kliniskt kemiska analyser, Post-analytisk stabilitet
National Category
Biomedical Laboratory Science/Technology
Identifiers
URN: urn:nbn:se:hj:diva-40070ISRN: JU-HHJ-BLA-1-20180066OAI: oai:DiVA.org:hj-40070DiVA, id: diva2:1215969
Subject / course
HHJ, Biomedical Laboratory Science
Supervisors
Examiners
Available from: 2018-06-21 Created: 2018-06-10 Last updated: 2018-06-21Bibliographically approved

Open Access in DiVA

fulltext(311 kB)16 downloads
File information
File name FULLTEXT01.pdfFile size 311 kBChecksum SHA-512
59830811c569c44041e1910e1678d4bfa50aed12ae5029aeac0a10520f0fbec6aa700f647098fa50e26d0473290f44b10ca1121bcc1756cd8b04b1e92493dd8c
Type fulltextMimetype application/pdf

By organisation
HHJ, Dep. of Natural Science and Biomedicine
Biomedical Laboratory Science/Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 16 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 43 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf