Lower Jaw Movements Measured by Optoelectronic Movement Recording: A pilot study
Umeå University, Faculty of Medicine, Department of Odontology.
Umeå University, Faculty of Medicine, Department of Odontology.
2018 (English)Independent thesis Advanced level (professional degree), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

Due to the complex nature of jaw movements, three-dimensional (3D) movement recording provide information about the jaw movement capacity. The aim of the present report was to test the reliability of measuring lower jaw movements using a 3D movement recording system and to calculate the lower jaw movement volume.

Lower jaw movements, recorded by 3D optoelectronic movement analysis system (MacReflex®) was compared with reference values from a digital caliper. Pre-tests were performed to develop a software to calculate the lower jaw movements in separate dimensions and its volume. Pilot tests with two test persons followed to register the lower jaw movements and calculate lower jaw movement volume.

The results indicate low reliability of lower jaw movements measured by movement recording system compared with reference values from digital caliper, reflected by delta values (D = max-min). The values from the movement recording system indicate high variability reflected by higher levels of standard deviation for movement recorded values compared with digital caliper and by percentage values calculated from the differences between mean values of movement recording and digital caliper. The calculated lower jaw movement volume was 10.3 cm3 and 17.2 cm3 for the test persons, respectively.

Conclusively, the results imply that further testing of the method is needed with larger series and test-retest reliability analysis to evaluate the possibility to improve accuracy of tracing jaw movements with recording device. The 3D-movement recording system together with the software could be used for calculation of lower jaw movement volume but its accuracy could not be validated.

Place, publisher, year, edition, pages
2018. , p. 25
Keyword [en]
Lower Jaw Movements. Optoelectronic Movement Recording. Mandibular movement. Volume.
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:umu:diva-143860OAI: oai:DiVA.org:umu-143860DiVA, id: diva2:1173036
External cooperation
Helena Grip; VLL
Educational program
Dentistry Programme
Presentation
2017-10-16, Umeå Universitet, Umeå, 13:21
Supervisors
Examiners
Available from: 2018-01-11 Created: 2018-01-11 Last updated: 2018-01-11Bibliographically approved

Open Access in DiVA

fulltext(788 kB)36 downloads
File information
File name FULLTEXT01.pdfFile size 788 kBChecksum SHA-512
c3118a05809be44645cb76c93303e2f418616cfa6b19abe47abfa220a9b087dcefebee125f01e005c5be8af6f46935f31fc3856956336970209fb0d423093f75
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Wänman, Magnus
By organisation
Department of Odontology
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
Total: 36 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 71 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf