Magnetic Resonance Imaging of Myocardial Deformation and Scarring in Coronary Artery Disease.
Linköping University, Department of Medical and Health Sciences, Division of Radiological Sciences. Linköping University, Faculty of Medicine and Health Sciences. Linköping University, Center for Medical Image Science and Visualization (CMIV). Region Östergötland, Center for Diagnostics, Department of Radiology in Linköping.ORCID iD: 0000-0003-3124-8044
2017 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Although improved treatments have reduced the rates of acute complications from myocardial infarction, sequelae such as heart failure and sudden death threaten the future wellbeing of those patients. Secondary prevention after myocardial infarction is related to cardiovascular risk factors and the effect of the infarct on left ventricular function. Cardiovascular magnetic resonance imaging (CMR) is necessary to determine the size of the infarct scar and can with great precision determine left ventricular volumes, left ventricular ejection fraction, and deformation (strain and torsion). The purpose of this thesis was to improve on CMR methods to facilitate image acquisition and post processing in patients with high risk of coronary artery disease (CAD).

In Paper 1, a three-dimensional phase-sensitive inversion-recovery (3D PSIR) sequence was modified to measure T1 during a single breath hold. The measured T1 values were used to extrapolate a map of T1 relaxation, which avoided the time-consuming manual determination of the inversion time. The data collection consisted of phantom experiments, Monte Carlo simulations of the effect of various heart rates, and clinical investigation of 18 patients with myocardial infarction. Scar images created with the modified sequence were compared to those created with the standard sequence. The 3D PSIR sequence was able to measure T1 relaxation with a high accuracy up to 800 ms, which is in the suitable range for scar imaging. Simulated arrhythmias showed that the method was robust and able to tolerate some variation in heart rate. The modified sequence provides measurements of inversion time that can be used to facilitate standard scar imaging or to reconstruct synthetic scar images. Images of infarct scar obtained with the 3D PSIR sequence bore striking similarity to images obtained with the standard sequence.

In Paper 2, 125 patients with high risk of CAD were investigated using the displacement encoding with stimulated echoes (DENSE) sequence. Image segments with infarct scar area >50% (transmurality) could be identified with a sensitivity of 95% and a specificity of 80% based on circumferential strain calculated from the DENSE measurements. The DENSE sequence was also applied in other directions, but its sensitivity and specificity to detect scar was lower than when used for circumferential strain.

In Paper 3, 90 patients with high risk of CAD were examined by DENSE, tagging with harmonic phase (HARP) imaging and cine imaging with feature tracking (FT), to detect cardiac abnormalities as manifested in end-systolic circumferential strain. Circumferential strain calculated with DENSE had higher sensitivity and specificity than the competing methods to detect infarction with transmurality >50%. Global circumferential strain measured by DENSE correlated better with global parameters such as left ventricular ejection fraction, myocardial wall mass, left ventricular end-diastolic and end-systolic volume; than strain measured by FT or HARP.

In Paper 4, myocardial torsion was investigated using DENSE, HARP, and FT in 48 patients with high risk of CAD. Torsion measured by each of the three methods was correlated with other global measures such as left ventricular ejection fraction, left ventricular mass, and left ventricular end-diastolic and end-systolic volumes. The torsion measurements obtained with DENSE had a stronger relationship with left ventricular ejection fraction, left ventricular mass, and volumes than those obtained with HARP or FT.

DENSE was superior to the other methods for strain and torsion measurement and can be used to describe myocardial deformation quantitatively and objectively.

Place, publisher, year, edition, pages
Linköping: Linköping University Electronic Press, 2017. , p. 61
Series
Linköping University Medical Dissertations, ISSN 0345-0082 ; 1595
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
URN: urn:nbn:se:liu:diva-143028DOI: 10.3384/diss.diva-143028ISBN: 9789176854310 (print)OAI: oai:DiVA.org:liu-143028DiVA, id: diva2:1157306
Public defence
2017-12-07, Berzeliussalen, Campus US, Linköping, 09:00 (English)
Opponent
Supervisors
Available from: 2017-11-15 Created: 2017-11-15 Last updated: 2017-11-15Bibliographically approved
List of papers
1. Rapid T1 quantification based on 3D phase sensitive inversion recovery
Open this publication in new window or tab >>Rapid T1 quantification based on 3D phase sensitive inversion recovery
2010 (English)In: BMC Medical Imaging, ISSN 1471-2342, E-ISSN 1471-2342, Vol. 10, no 19Article in journal (Refereed) Published
Abstract [en]

BACKGROUND: In Contrast Enhanced Magnetic Resonance Imaging fibrotic myocardium can be distinguished from healthy tissue using the difference in the longitudinal T1 relaxation after administration of Gadolinium, the so-called Late Gd Enhancement. The purpose of this work was to measure the myocardial absolute T1 post-Gd from a single breath-hold 3D Phase Sensitivity Inversion Recovery sequence (PSIR). Equations were derived to take the acquisition and saturation effects on the magnetization into account.

METHODS: The accuracy of the method was investigated on phantoms and using simulations. The method was applied to a group of patients with suspected myocardial infarction where the absolute difference in relaxation of healthy and fibrotic myocardium was measured at about 15 minutes post-contrast. The evolution of the absolute R1 relaxation rate (1/T1) over time after contrast injection was followed for one patient and compared to T1 mapping using Look-Locker. Based on the T1 maps synthetic LGE images were reconstructed and compared to the conventional LGE images.

RESULTS: The fitting algorithm is robust against variation in acquisition flip angle, the inversion delay time and cardiac arrhythmia. The observed relaxation rate of the myocardium is 1.2 s-1, increasing to 6 - 7 s-1 after contrast injection and decreasing to 2 - 2.5 s-1 for healthy myocardium and to 3.5 - 4 s-1 for fibrotic myocardium. Synthesized images based on the T1 maps correspond very well to actual LGE images.

CONCLUSIONS: The method provides a robust quantification of post-Gd T1 relaxation for a complete cardiac volume within a single breath-hold.

National Category
Engineering and Technology Medical and Health Sciences
Identifiers
urn:nbn:se:liu:diva-59065 (URN)10.1186/1471-2342-10-19 (DOI)20716333 (PubMedID)
Available from: 2010-09-08 Created: 2010-09-08 Last updated: 2017-12-12
2. Clinical experience of strain imaging using DENSE for detecting infarcted cardiac segments
Open this publication in new window or tab >>Clinical experience of strain imaging using DENSE for detecting infarcted cardiac segments
Show others...
2015 (English)In: Journal of Cardiovascular Magnetic Resonance, ISSN 1097-6647, E-ISSN 1532-429X, Vol. 17, article id 50Article in journal (Refereed) Published
Abstract [en]

Background

We hypothesised that myocardial deformation determined with magnetic resonance imaging (MRI) will detect myocardial scar.

Methods

Displacement Encoding with Stimulated Echoes (DENSE) was used to calculate left ventricular strain in 125 patients (29 women and 96 men) with suspected coronary artery disease. The patients also underwent cine imaging and late gadolinium enhancement. 57 patients had a scar area >1 % in at least one segment, 23 were considered free from coronary artery disease (control group) and 45 had pathological findings but no scar (mixed group). Peak strain was calculated in eight combinations: radial and circumferential strain in transmural, subendocardial and epicardial layers derived from short axis acquisition, and transmural longitudinal and radial strain derived from long axis acquisitions. In addition, the difference between strain in affected segments and reference segments, “differential strain”, from the control group was analysed.

Results

In receiver-operator-characteristic analysis for the detection of 50 % transmurality, circumferential strain performed best with area-under-curve (AUC) of 0.94. Using a cut-off value of -17 %, sensitivity was 95 % at a specificity of 80 %. AUC did not further improve with differential strain. There were significant differences between the control group and global strain circumferential direction (-17 % versus -12 %) and in the longitudinal direction (-13 % versus -10 %). Interobserver and scan-rescan reproducibility was high with an intraclass correlation coefficient (ICC) >0.93.

Conclusions

DENSE-derived circumferential strain may be used for the detection of myocardial segments with >50 % scar area. The repeatability of strain is satisfactory. DENSE-derived global strain agrees with other global measures of left ventricular ejection fraction.

Place, publisher, year, edition, pages
BioMed Central, 2015
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
urn:nbn:se:liu:diva-119846 (URN)10.1186/s12968-015-0155-8 (DOI)000356652000001 ()26104510 (PubMedID)
Available from: 2015-06-26 Created: 2015-06-26 Last updated: 2017-12-04

Open Access in DiVA

Magnetic Resonance Imaging of Myocardial Deformation and Scarring in Coronary Artery Disease.(1423 kB)76 downloads
File information
File name FULLTEXT01.pdfFile size 1423 kBChecksum SHA-512
cad58177895c5b423b9ca9a4e92f2a7a0d1cc6f3b14db0c787f9fb6938e8c3c9445e2f37dc43c54e37adcfbf3d575d903b75d41efdb004bea8b3d47946b275f6
Type fulltextMimetype application/pdf
omslag(96 kB)3 downloads
File information
File name COVER01.pdfFile size 96 kBChecksum SHA-512
84f5af7bc7c02d94e3d1e1d41b4c9318b94877905de8003f11fb1ec36d46057d264110bc2b82f44e1ff5161511b9e89575427d64fb5a62c266ccd2ecf5476070
Type coverMimetype application/pdf

Other links

Publisher's full text

Search in DiVA

By author/editor
Kihlberg, Johan
By organisation
Division of Radiological SciencesFaculty of Medicine and Health SciencesCenter for Medical Image Science and Visualization (CMIV)Department of Radiology in Linköping
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
Total: 76 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
isbn
urn-nbn

Altmetric score

doi
isbn
urn-nbn
Total: 913 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf