The accuracy of postoperative, non-invasive Air-Test to diagnose atelectasis in healthy patients after surgery: a prospective, diagnostic pilot study
Hosp Clin Univ Valencia, Anesthesiol & Crit Care, Valencia, Spain..
Consorci Hosp Gen Univ Valencia, Anesthesiol & Crit Care, Valencia, Spain..
Hosp Privado Comunidad Mar Del Plata, Dept Anesthesiol, Mar De Plata, Argentina..
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Surgical Sciences, Hedenstierna laboratory. Inst Salud Carlos III, CIBER Enfermedades Resp, Madrid, Spain..ORCID iD: 0000-0002-7412-2970
Show others and affiliations
2017 (English)In: BMJ Open, ISSN 2044-6055, E-ISSN 2044-6055, Vol. 7, no 5, article id e015560Article in journal (Refereed) Published
Abstract [en]

Objective To assess the diagnostic accuracy of peripheral capillary oxygen saturation (SpO(2)) while breathing room air for 5 min (the 'Air-Test') in detecting postoperative atelectasis. Design Prospective cohort study. Diagnostic accuracy was assessed by measuring the agreement between the index test and the reference standard CT scan images. Setting Postanaesthetic care unit in a tertiary hospital in Spain. Participants Three hundred and fifty patients from 12 January to 7 February 2015; 170 patients scheduled for surgery under general anaesthesia who were admitted into the postsurgical unit were included. Intervention The Air-Test was performed in conscious extubated patients after a 30 min stabilisation period during which they received supplemental oxygen therapy via a venturi mask. The Air-Test was defined as positive when SpO(2) was >= 96% and negative when SpO(2) was >= 97%. Arterial blood gases were measured in all patients at the end of the Air-Test. In the subsequent 25 min, the presence of atelectasis was evaluated by performing a CT scan in 59 randomly selected patients. Main outcome measures The primary study outcome was assessment of the accuracy of the Air-Test for detecting postoperative atelectasis compared with the reference standard. The secondary outcome was the incidence of positive Air-Test results. Results The Air-Test diagnosed postoperative atelectasis with an area under the receiver operating characteristic curve of 0.90 (95% CI 0.82 to 0.98) with a sensitivity of 82.6% and a specificity of 87.8%. The presence of atelectasis was confirmed by CT scans in all patients (30/30) with positive and in 5 patients (17%) with negative Air-Test results. Based on the Air-Test, postoperative atelectasis was present in 36% of the patients (62 out of 170). Conclusion The Air-Test may represent an accurate, simple, inexpensive and non-invasive method for diagnosing postoperative atelectasis.

Place, publisher, year, edition, pages
2017. Vol. 7, no 5, article id e015560
National Category
Anesthesiology and Intensive Care
Identifiers
URN: urn:nbn:se:uu:diva-329118DOI: 10.1136/bmjopen-2016-015560ISI: 000402533300113OAI: oai:DiVA.org:uu-329118DiVA, id: diva2:1150384
Available from: 2017-10-18 Created: 2017-10-18 Last updated: 2017-11-29Bibliographically approved

Open Access in DiVA

fulltext(617 kB)9 downloads
File information
File name FULLTEXT01.pdfFile size 617 kBChecksum SHA-512
6dc5a5600bfb777fa6ef2de7d74dd9c537159945a53e52212d3a654c05ad5ee2f6daab5816a95bc3b773c79695a211b03eb537c9da2cc4b53d62f998a966d8c0
Type fulltextMimetype application/pdf

Other links

Publisher's full text

Search in DiVA

By author/editor
Suarez-Sipmann, Fernando
By organisation
Hedenstierna laboratory
In the same journal
BMJ Open
Anesthesiology and Intensive Care

Search outside of DiVA

GoogleGoogle Scholar
Total: 9 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 132 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf