MR-OPERA: a multicenter/multivendor validation of magnetic resonance imaging–only prostate treatment planning using synthetic computed tomography images
Show others and affiliations
2017 (English)In: International Journal of Radiation Oncology, Biology, Physics, ISSN 0360-3016, E-ISSN 1879-355X, Vol. 99, no 3, p. 692-700Article in journal (Refereed) Published
Abstract [en]

Purpose: To validate the dosimetric accuracy and clinical robustness of a commercially available software for magnetic resonance (MR) to synthetic computed tomography (sCT) conversion, in an MR imaging–only workflow for 170 prostate cancer patients.

Methods and Materials: The 4 participating centers had MriPlanner (Spectronic Medical), an atlas-based sCT generation software, installed as a cloud-based service. A T2-weighted MR sequence, covering the body contour, was added to the clinical protocol. The MR images were sent from the MR scanner workstation to the MriPlanner platform. The sCT was automatically returned to the treatment planning system. Four MR scanners and 2 magnetic field strengths were included in the study. For each patient, a CT-treatment plan was created and approved according to clinical practice. The sCT was rigidly registered to the CT, and the clinical treatment plan was recalculated on the sCT. The dose distributions from the CT plan and the sCT plan were compared according to a set of dose-volume histogram parameters and gamma evaluation. Treatment techniques included volumetric modulated arc therapy, intensity modulated radiation therapy, and conventional treatment using 2 treatment planning systems and different dose calculation algorithms.

Results: The overall (multicenter/multivendor) mean dose differences between sCT and CT dose distributions were below 0.3% for all evaluated organs and targets. Gamma evaluation showed a mean pass rate of 99.12% (0.63%, 1 SD) in the complete body volume and 99.97% (0.13%, 1 SD) in the planning target volume using a 2%/2-mm global gamma criteria.

Conclusions: Results of the study show that the sCT conversion method can be used clinically, with minimal differences between sCT and CT dose distributions for target and relevant organs at risk. The small differences seen are consistent between centers, indicating that an MR imaging–only workflow using MriPlanner is robust for a variety of field strengths, vendors, and treatment techniques.

Place, publisher, year, edition, pages
Elsevier, 2017. Vol. 99, no 3, p. 692-700
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
URN: urn:nbn:se:umu:diva-140632DOI: 10.1016/j.ijrobp.2017.06.006ISI: 000411225300032OAI: oai:DiVA.org:umu-140632DiVA, id: diva2:1150367
Available from: 2017-10-18 Created: 2017-10-18 Last updated: 2018-06-09Bibliographically approved

Open Access in DiVA

fulltext(1533 kB)28 downloads
File information
File name FULLTEXT01.pdfFile size 1533 kBChecksum SHA-512
9918a9e7badbe24772192db5c96c6c7b1d8fcea75236efd0e0a38e434ca276c7fd479f1346e40979d8516df242d1050cbc7b542a5bbe48772b28b945da4c36ae
Type fulltextMimetype application/pdf

Other links

Publisher's full text

Search in DiVA

By author/editor
Blomqvist, LennartZackrisson, BjörnNyholm, TufveJonsson, Joakim
By organisation
Department of Radiation Sciences
In the same journal
International Journal of Radiation Oncology, Biology, Physics
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
Total: 28 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 133 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf