Secondary Fluid Impact on Ice Rink Refrigeration System Performance
KTH, School of Industrial Engineering and Management (ITM), Energy Technology.ORCID iD: 0000-0001-8516-0609
Energi & Kylanalys.
KTH, School of Industrial Engineering and Management (ITM), Energy Technology.
Show others and affiliations
2014 (English)Conference paper, Published paper (Refereed)
Abstract [en]

Sweden has 352 ice rinks in operation which annually use approximately 1000MWh. A refrigeration system usually accounts for about 43% of the total energy consumption and can present a significant energy saving potential. More than 97% of the Swedish ice rinks use indirect refrigeration system and thermo-physical properties of secondary fluid have a direct impact on the heat transfer and pressure drop. A theoretical model and two case studies focusing on the importance of the secondary fluid choice were investigated. The results showed that potassium formate had the best heat transfer properties while ammonia lead to the lowest pressure drops and pumping power. Propylene glycol showed the worst performance in both cases. Ammonia and potassium formate showed respectively 5% and 3% higher COP than calcium chloride for typical heat loads of 150kW. When controlling the pump over a temperature difference (ΔT), the existence of the optimum pump control or optimum flow was highlighted. For typical cooling capacity of 150kW optimum pump control temperature difference ΔT was around 2,5K for calcium chloride and around 2K for ammonia. Järfälla case study showed a potential energy saving of 12% for the refrigeration system when increasing the freezing point of the secondary fluid. An energy saving of around 10,8 MWh/yr per 1K increase of the secondary fluid freezing point was found.

Place, publisher, year, edition, pages
2014.
Keywords [en]
ice rink, secondary fluid, refrigeration system, heat transfer, pressure drop
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:kth:diva-215743OAI: oai:DiVA.org:kth-215743DiVA, id: diva2:1149258
Conference
11thIEA Heat Pump Conference 2014, May 12-16 2014, Montréal (Québec) Canada
Note

QC 20171102

Available from: 2017-10-14 Created: 2017-10-14 Last updated: 2017-11-02Bibliographically approved

Open Access in DiVA

SECONDARY FLUID IMPACT ON ICE RINK REFRIGERATION SYSTEM PERFORMANCE(300 kB)17 downloads
File information
File name FULLTEXT01.pdfFile size 300 kBChecksum SHA-512
10d175dd166d6620fa40a7ea86e175c3d90829aa09ffe77c0e2ceb862207be57d5d153cbb1ee1c341232b4068b4cb458a565cb50db4866b05a6f9896e20b5168
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Ignatowicz, MonikaMazzotti, WillemMelinder, ÅkePalm, Björn
By organisation
Energy Technology
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 17 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 66 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf