Färgade kontaktlinsers påverkan på visus och okulära aberrationer
Linnaeus University, Faculty of Health and Life Sciences, Department of Medicine and Optometry.
2017 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Syfte: Syftet med denna studie var att se om två olika pupilltyper av kosmetiskt färgade kontaktlinser i samma färg påverkade synkvaliteten genom visus och högre ordningens aberrationer och om resultaten skiljde sig från ofärgade linser.

Metod: 35 försökspersoner delades in i 3 olika grupper där varje grupp testade en typ av kontaktlins: färgade linser med 5mm pupill, helfärgade utan klar central zon och ofärgade. Visus och aberrationer mättes före linsbärande, efter 6 timmars linsbärande och efter linserna tagits av. Mätningarna gjordes med en COAS-HD VR aberrometer och resultaten analyserades med mixed model ANOVA.

Resultat: Visus för den ofärgade linsgruppen minskade 0,06 decimal med lins och gruppen med helfärgade minskade 0,10 decimal med lins och båda ökade igen efter linsbärande. Gruppen med färgade linser med öppen pupill minskade 0,06 decimal med lins och stannade kvar på samma värde efter linsbärande. Ingen av linstyperna visade någon signifikant reducering av visus. HOA RMS för ofärgade linser ökade från 0,165±0,04μm till 0,224±0,05μm och gick tillbaka till 0,173±0,03μm. Helfärgade gick från 0,149±0,03μm till 0,240±0,14μm och sjönk sedan till 0,159±0,05μm. Öppen pupill började på 0,193±0,05 μm ökade till 0,398±0,07μm och sjönk till 0,203±0,08μm.

Slutsats: Ingen av de 3 kontaktlinstyperna som användes gav någon signifikant reducering av visus varken när linsen var på eller efter den tagits av. Ökningen av den totala mängden högre ordningens aberrationer var endast signifikant då linsen var på och mängden aberrationer var signifikant högre för linsdesignen med öppen pupill.

Abstract [en]

The aim of this study was to see if two different types of cosmetically tinted contact lenses affected the visual quality and higher order aberrations and if the results differed from clear lenses. Thirtyfive subjects were divided into three different groups where each group tested one type of contact lens. The lens types were tinted lenses with a clear zone of 5mm, tinted lenses with no clear zone and clear lenses with only a handling tint. Visual acuity and aberrations were measured at baseline, after 6 hours of lens wear and after removal of the lens. The measurements were made with a COAS-HD VR aberrometer and the results were analyzed by mixed model ANOVA. Visual acuity with lens wear for all the three groups reduced by 0.06 (clear lens), 0.10 (closed pupil) and 0.06 (open pupil) compared to the baseline acuity measurements without lens. After lens removal both the clear group and tinted with no clear zone group visual acuities returned to baseline values. Furthermore, visual acuity in the open pupil group after lens removal remained similar to that of lens wear and did not return to the baseline value. However, the reduction in visual acuity with lens wear was very minimal and there was no statistically significant change in visual acuity between lens wear condition and between the three groups (p>0.05). HOA RMS for clear lenses increased from 0.165 ± 0.04μm to 0.224 ± 0.05μm with lens and then decreased to 0.173 ± 0.03μm. Tinted with no clear zone group went from 0.149 ± 0.03μm to 0.240 ± 0.14μm and then decreased to 0.159 ± 0.05μm. Open pupil group started at 0.193 ± 0.05 μm increased to 0.398 ± 0.07μm and dropped to 0.203 ± 0.08μm. None of the three contact lens types used gave any significant reduction of visual acuity either when the lens was on or after it had been removed (p>0.05). The increase in the total amount of higher order aberrations was only significant when the lens was worn and we found significantly higher amount of aberrations in the open pupil design (p<0.05).

Place, publisher, year, edition, pages
2017. , 19 p.
Keyword [sv]
Färgade kontaktlinser, högre ordningens aberrationer, visus
National Category
Natural Sciences
Identifiers
URN: urn:nbn:se:lnu:diva-65997OAI: oai:DiVA.org:lnu-65997DiVA: diva2:1118444
Educational program
Optometry Programme, 180 credits
Supervisors
Examiners
Available from: 2017-07-06 Created: 2017-06-30 Last updated: 2017-07-06Bibliographically approved

Open Access in DiVA

fulltext(416 kB)19 downloads
File information
File name FULLTEXT01.pdfFile size 416 kBChecksum SHA-512
846eb32c80f65029f84ddd77ea6bd14482514ab6cbc3462997ad8bb0d9733b71313608576a17333a296fc4224c06e1af8029600423f1e84348668b765a34865e
Type fulltextMimetype application/pdf

By organisation
Department of Medicine and Optometry
Natural Sciences

Search outside of DiVA

GoogleGoogle Scholar
Total: 19 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 34 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf