Förbättringsåtgärder vid nybyggnation av småhus för att uppnå kommande energikrav: En simuleringsstudie i IDA ICE
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building, Energy and Environmental Engineering.
2017 (Swedish)Independent thesis Advanced level (degree of Master (Two Years)), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

EU har ställt höga krav på energianvändning i byggnader genom ett nytt direktiv där respektive medlemsland har fått i uppdrag att ta fram gränsvärden för energianvändning i just sitt land. I Sverige har Boverket fått detta ansvar. I och med det skärpta krav som har föreslagits finns en orolighet i byggbranschen att det kommer att bli svårt att uppfylla det. Tillverkare av småhushar ofta en standardiserad konstruktion som de nu kan behöva ändra på.

Syftet med detta examensarbete blev därför att undersöka om en småhustillverkare behöver förändra sin standardkonstruktion, och i så fall vilka förändringar som kan göras, för att uppnå det nya kravet för energianvändning.

Genom att studera nuvarande energikrav och Boverkets förslag på nytt krav samt teorier inom byggnadskonstruktion har den teoretiska grunden för examensarbetet lagts. En litteraturstudie har dessutom gjorts över tidigare studier inom området, där framför allt förbättringsåtgärder för att få energisnålare hus har varit till stor hjälp för detta arbete. Studien av en småhustillverkare har genomförts genom att energianvändningen av ett småhus i standardutförande har tagits fram i simuleringsprogrammet IDA ICE. Studerat hus är en trävilla med bergvärme och FTX-ventilation beläget i klimatzon 1. Efter simuleringen har åtta förbättringar i husets konstruktion gjorts med nya simuleringar för att identifiera vilka av dessa förbättringar som är lämpliga att utföra. De mest lämpade förbättringarna har slutligen kombinerats ihop för att uppnå det nya energikravet.

Studien visar att nuvarande konstruktion inte uppfyller kommande krav. Utifrån de avgränsningar som har gjorts rekommenderas att följande tre åtgärder vidtas; installation av en värmepump med COP 4 istället för 3, fönster och dörrar med U-värde 0,8 W/(m2*K) istället för 1,2 W/(m2*K) samt ytterväggar med U-värde 0,1 W/(m2*K) istället för 0,137 W/(m2*K). Dessa rekommendationer utgår från att det föreslagna kravet även gäller för klimatzon 1.

Abstract [en]

The EU has demanded lower energy consumption in buildings through a new directive where each member state has been assigned the task of developing new energy consumption targets for their respective country. In Sweden, Boverket has been assigned this responsibility. There is a concern in the Swedish construction industry that it will be difficult to meet these new requirements. Manufacturers of small houses usually have a standardized design that they now may need to adjust.

The purpose of this thesis was therefore to investigate whether a single-family house manufacturer needs to change its standard construction, and if so, what changes could be made to achieve the new requirements for energy usage.

By studying current energy requirements and Boverket's proposal for future requirements as well as theories in architectural engineering, the theoretical basis for the thesis has been laid out. A literature study has also been performed of previous studies in the field. Particularly studies of home improvements to get energy-efficient houses have been of great help for this work. A single-family house has been constructed and simulated in the IDA ICE simulation program. The house was made out of wood with a ground source heat pump and FTX ventilation located in climate zone 1. Eight improvements in the house design have been studied with new simulations to identify which of these improvements are appropriate to implement. The most suitable improvements have finally been combined to meet the new energy requirements.

The study shows that the current house construction design does not meet future requirements. Based on the delimitations that have been made for this thesis, it is recommended that the following three measures are to be taken; A heat pump with a COP of 4 instead of 3, windows and doors with a U-value of 0.8 W/(m2*K) instead of 1,2 W/(m2*K) and outer walls with a U-value of 0.1 W/(m2*K) instead of 0,137 W/(m2*K). These recommendations are based on the assumption that the proposed new requirements are also applicable for climate zone 1.

Place, publisher, year, edition, pages
2017. , p. 34
Keywords [en]
energy requirements, energy usage, energy s vings, new construction, building construction regulations, energy simulation, energy analysis, IDA ICE
Keywords [sv]
energikrav, energianvändning, energibesparing, nybyggnation, Boverkets byggregler, energisimulering, energianalys, IDA ICE
National Category
Energy Systems
Identifiers
URN: urn:nbn:se:hig:diva-24364OAI: oai:DiVA.org:hig-24364DiVA, id: diva2:1111709
Subject / course
Energy systems
Educational program
Energy systems – master’s programme (two years)
Supervisors
Examiners
Available from: 2017-08-04 Created: 2017-06-19 Last updated: 2017-08-04Bibliographically approved

Open Access in DiVA

fulltext(6692 kB)58 downloads
File information
File name FULLTEXT01.pdfFile size 6692 kBChecksum SHA-512
01b81096b8cc087e66d013dc680a0a3c4159a9cb2e71c138219182416132f0e89551a99738758fbdec864d62b5e97e6bc6aa3952919ffb47b9b68ce3756dc60d
Type fulltextMimetype application/pdf

By organisation
Department of Building, Energy and Environmental Engineering
Energy Systems

Search outside of DiVA

GoogleGoogle Scholar
Total: 58 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 198 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf