Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Realtidsimplementation av metod för att förbättra kontrasten mellan blod- och kärlvävnad vid ultraljudsundersökning: Eulerian Video Magnification implementering på ultraljudssystemet Ultrasonix
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.
2017 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesisAlternative title
Real-time implementation of method to improve the contrast between blood and vascular tissue in ultrasound examination : Eulerian Video Magnification implementation on Ultrasonix ultrasound system (English)
Abstract [sv]

I en vanlig ultraljudsbild har man låg kontrast mellan vävnader som har en liknande akustisk impendans. Detta orsakar problem när man försöker detektera plack i kärlen som har liknande akustisk impedans som blodet. Dessa plack är ofta de som är farliga för en människa eftersom de kan orsaka en stroke eller infarkt. Projektets mål är att implementera en videobehandlingsmetod som ska förbättra kontrasten mellan blod och kärlvävnad i realtid. Denna ska implementeras på ultraljudssystemet från Ultrasonix. Detta ska hjälpa sjukvårdpersonalen att bättre kunna se skillnaden mellan de olika vävnaderna i ultrlajudsbilder. För att kunna göra detta användes en videobehandlingsmetod som förstärker skillnader i färg och rörelse i en video kopplat till en önskad frekvens. Metoden kallas för Eulerian Video Magnification och den använder sig av spatial och temporal filtrering. Arbetet börjades med att undersöka de realtidslösningarna som redan fanns och försöka hitta vad som gav bästa resultatet för just det här projektet. Programvarubiblioteket OpenCV användes för realtidsbildbehandlingen. Genom att studera andras arbeten kunde en lösning för spatial och temporal filtrering implementeras. En testkod kördes på en vanlig dator och implementerades sedan på ultraljudssystemet Ultrasonix. Resultatet i projektetet är att man kan se ett förstärkt blodflöde i ultraljudsbilder i realtid. Detta syns i form av att kärlet lyses upp i takten att blodet pumpas vidare i kärlet. En utvärdering för implementeringen gjordes med hjälp av fem frivilliga testpersoner. Denna utvärdering visade att metoden fungerar om störningarna från venen försöker minimeras. För att resultatet ska bli bättre krävs det vidare utveckling med det spatiala och temporala filtret för att försöka filtrera bort dessa störningar bättre.

Abstract [en]

In a normal ultrasound image, there is low contrast between tissues that have similar acoustic impendance. This causes problems when trying to detect plaques in the bloodvessels that have similar acoustic impedance as the blood. These plaques are often those that are dangerous because they can cause a stroke or infarction. This project's aim is to implement a video-processing method that will improve the contrast between blood and vascular tissue in real time. This will be implemented on the Ultrasonix ultrasoundsystem. The purpose is to help healthcare professionals to better see the difference between these different tissues in ultrasound images. In order to do this, a video processing method that enhances color differences in a video connected to a desired frequency was used. This method is called Eulerian Video Magnification and it uses spatial and temporal filtering. The work began by investigating the real-time solutions that already excisted. The goal of this was to find the solution that gave the best results in this particular project. The OpenCV software library was used for real-time image processing. By studying other people's work, a solution for spatial and temporal filtering could be implemented. A test code was run on a computer and then implemented on Ultrasonix ultrasoundsystem. As a result a boosted bloodflow in ultrasound images could be seen. An evaluation of the implementation was done using five voluntary test subjects. The result from the evaluation was that the method works if the disorders from the vein are minimized. In order to get better results, further development is required with the spatial and temporal filter to filter these disordes better.

Place, publisher, year, edition, pages
2017. , 25 p.
National Category
Medical Engineering
Identifiers
URN: urn:nbn:se:umu:diva-136264OAI: oai:DiVA.org:umu-136264DiVA: diva2:1110100
External cooperation
Norrlands Universitetssjukhus, CMTS, Medicinsk teknik - FoU
Subject / course
Elektronik
Educational program
Bachelor of Science Programme in Electronic and Computer Engeneering/ Medical engineering
Supervisors
Examiners
Available from: 2017-06-15 Created: 2017-06-15 Last updated: 2017-06-15Bibliographically approved

Open Access in DiVA

fulltext(781 kB)11 downloads
File information
File name FULLTEXT01.pdfFile size 781 kBChecksum SHA-512
2d25144bbcde8fe0b5815661a9b749b7c5a9156722633140b95f743c11c439515a9d25c3dc32aed6f749a43dba05d6f893a44a97be406e214b62463149a73a16
Type fulltextMimetype application/pdf

By organisation
Department of Applied Physics and Electronics
Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 11 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 21 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf