En extra fasadskivas effekt på energiprestandan hos ett flerbostadshus: En kontroll av Boverkets krav för nära-nollenergibyggnader till 2021
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.
2017 (Swedish)Independent thesis Advanced level (professional degree), 20 credits / 30 HE creditsStudent thesisAlternative title
An additional facade board's effect on the energy performance of an apartment building : A verification of the requirements for nearly zero-energy buildings for 2021 (English)
Abstract [en]

Increasing the energy efficiency of buildings and the introduction of more strict regulations are small but important steps towards a better climate. Today the housing and services sector stands for nearly 40 % of Sweden’s energy use. To push the development towards more energy efficient buildings in Europe, all the new buildings are required to be nearly zero-energy buildings by 2021.

The purpose of this project was to evaluate whether the use of an additional facade board on an apartment building results in putting the energy performance within the current energy performance requirements, and also within the future requirements for nearly zero-energy buildings (NZEBs). The facade boards that were tested in this project are manufactured by Kingspan and Isover. The different boards were tested in thicknesses of 30 and 50 mm. The aim of the project was to calculate the building’s average heat transfer coefficient, specific energy use and primary energy number (PET) using COMSOL Multiphysics (CM) and IDA Indoor Climate and Energy (IDA ICE). The results were then about to be controlled against the current energy performance requirements together with the future requirements for NZEBs.

The approach of this project consisted of the use of the softwares CM and IDA ICE. Because IDA ICE requires input of the thermal bridges of the building, CM was used to simulate these. This was done in order to achieve more reliable values than if an assumption was made or a standard value was used. A model of the building was then created in IDA ICE where its energy performance and average heat transfer coefficient were obtained from simulations over a normal year.

The results obtained from the simulations in CM seemed credible as the use of the best facade board caused the values of the thermal bridges to end up at ”Good” according to IDA ICE’s built in scale. The simulations in IDA ICE showed that the specific energy use of the bulding without an additional facade board was 55,9 kWh/m2,year compared to Boverket’s current requirements at 80 kWh/m2,year. With the 50 mm Kingspan facade board, the board with the best result, the specific energy use was reduced to 53 kWh/m2,year, an improvement of 5,2 %. For the case without an additional facade board, the PET was 66,6 kWh/m2,year compared to the NZEBs requirements for 2018 at 85 kWh/m2,year together with the requirements for year 2021 at 65 kWh/m2,year. By using the 50 mm Kingspan facade board the PET was reduced to 63,3 kWh/m2,year, an improvement of 5,0 %. This resulted in putting the PET below the NZEB requirements for 2021. The facade board that resulted in the least energy savings, Isover P31 30 mm, had an improvement of 2,5 and 2,7 % for the specific energy use and the PET respectively. This facade board also resulted in putting the PET below the NZEB requirements for 2021.

The most obvious conclusions that could be drawn from the simulations was that the specific energy use was below the current energy performance requirements with a great margin, both with and without an additional facadeboard. The PET was well below theNZEB requirements for 2018 and was also belowthe NZEB requirements for 2021 using any of the tested facade boards. The building’s average heat transfer coefficient was also well below both today’s energy performance requirements and the NZEB requirements for 2018 and 2021. A use of an additional facade board resulted in an energy saving of around 2,5 and 5 % in the worst and the best case, respectively. Due to the neglect of the ring wall under the bulding, the energy performance is most probably slightly high. However, this is not of utmost relevance since the company normally does not use this kind of solution for their standard buildings. Other uncertainties about the choice of airflows in property spaces may have influenced the results in the other direction. If there are any other obvious energy saving measures than using an additional facade board, these should be taken into account primarily as a facade board can only reduce the energy use marginally.

Place, publisher, year, edition, pages
2017. , 38 p.
Keyword [sv]
Energi, IDA ICE, byggnad, nära-nollenergi, energikrav
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:umu:diva-136103OAI: oai:DiVA.org:umu-136103DiVA: diva2:1108977
External cooperation
Derome Plusshus AB
Subject / course
Energiteknik
Educational program
Master of Science Programme in Energy Engineering
Supervisors
Examiners
Available from: 2017-06-13 Created: 2017-06-13 Last updated: 2017-06-13Bibliographically approved

Open Access in DiVA

En extra fasadskivas effekt på energiprestandan hos ett flerbostadshus - en kontroll av Boverkets krav för nära-nollenergibyggnader till 2021(5966 kB)22 downloads
File information
File name FULLTEXT01.pdfFile size 5966 kBChecksum SHA-512
e1de77a81415c72ec5976ed2666eb968070a7e05b137298359f8c3aa59fac157eff1d556e078cb4feb8351782fa6031887d747f5f05b3596f5383c5116e02f67
Type fulltextMimetype application/pdf

By organisation
Department of Applied Physics and Electronics
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 22 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 85 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf