Framtida gasanvändning på Kalmar reningsverk: En ekonomisk jämförelse av olika investeringsmöjligheter
Linnaeus University, Faculty of Technology, Kalmar Maritime Academy.
Linnaeus University, Faculty of Technology, Kalmar Maritime Academy.
2017 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Då det finns planer på att ersätta det befintliga reningsverket i Kalmar inom en överskådlig framtid och nya krav om nödförsörjning av el har kommit från MSB, undersöktes möjligheten att använda den biogas som skulle komma att produceras på det nya reningsverket inom den egna verksamheten, istället för att som i dagsläget säljas.

I denna studie undersöktes lönsamheten i att antigen investera i en biogasdriven generator som i normalfall ger en besparing i el och fjärrvärme och kan leverera reservkraft vid spänningsbortfall på nätet, eller försäljning av biogasen och inköp av ett dieseldrivet reservkraftverk. 

Kostnadsförslag för biogasdrivna generatorer och reservkraftverk togs in. I denna ingick även service och komponenter för att kunna använda biogasen som bränsle. Utav kostnadsförslagen gjordes en LCC. Besparing av el och fjärrvärme samt förtjänst av försäljning av biogasen ställdes i relation mot varandra.

Arbetet konkluderar att, baserat på de uträkningar som gjordes, en ottomotor är det mest lönsamma för att generera el och värme för internt bruk.

Abstract [en]

Because of the plans to replace the old sewage treatment plant in Kalmar, which has come to the end of its life cycle, and due to new requirements of emergency supply from SCCA (Swedish Civil Contingencies Agency), the possibility of using the biogas on the plant itself was evaluated.

In this study, the profitability of two alternatives was evaluated. To invest in a biogas powered generator to produce electric power and heat, which would create savings in purchased electricity and district heating and work as an emergency generator, or to continue selling the biogas and invest in a diesel-powered emergency generator.

Cost estimates of biogas powered generators and the equipment needed for using the biogas as fuel was required from dealers and manufacturers. The cost estimates were then compiled in a LCC. The calculated savings and the income from selling the biogas was then added to the LCC, the alternatives was then compared to each other.

The study concludes that the most profitable alternative, based on the calculations, is to invest in a biogas powered generator and use the electricity and waste heat on the sewage plant.

Place, publisher, year, edition, pages
2017. , p. 20
Keywords [en]
Life Cycle Cost, Present Value of Annuity, Biogas, Combined Heat and Power Production
Keywords [sv]
Livscykelkostnad, nuvärdemetoden, biogas, kraftvärmeproduktion
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:lnu:diva-62595OAI: oai:DiVA.org:lnu-62595DiVA, id: diva2:1090986
External cooperation
Kalmar Reningverk
Subject / course
Chief Engineer
Educational program
Marine Engineering Programme (4 years) with onboard practical training placement, 180 credits
Presentation
2017-04-11, B211, Landgången 4, Kalmar, 16:00 (Swedish)
Supervisors
Examiners
Available from: 2017-04-26 Created: 2017-04-25 Last updated: 2017-04-26Bibliographically approved

Open Access in DiVA

fulltext(941 kB)32 downloads
File information
File name FULLTEXT01.pdfFile size 941 kBChecksum SHA-512
437b63a13f338bbac259d8118b9cadd98706b045f591e8e931e11830963e33ee40e114bcd9d77c36437ed3a521f99f5a63ad3e231c604405d1f6625880368f8f
Type fulltextMimetype application/pdf

By organisation
Kalmar Maritime Academy
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 32 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 179 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf