INVESTIGATION OF THE EFFECT OF THE TRANSFORMER CONNECTION TYPE ON VOLTAGE UNBALANCE PROPAGATION: CASE STUDY AT NÄSUDDEN WIND FARM
Uppsala University, Disciplinary Domain of Science and Technology, Earth Sciences, Department of Earth Sciences.
2016 (English)Independent thesis Advanced level (degree of Master (One Year)), 10 credits / 15 HE creditsStudent thesis
Abstract [en]

The objective of this Thesis is to investigate the phenomenon of voltage unbalance on electrical wind power systems. A large part of this work is the literature review of all relative work that has been done so far. This serves first as a guideline to define and measure voltage unbalance and second as a tool to spot open research questions that can inspire future work.

A case study is then used to investigate the voltage unbalance at a wind farm in Näsudden, Gotland. Using real-time measurements and a simulation of the power system in MATLAB/Simulink, an evaluation of the propagation of the voltage unbalance from the distribution to the turbine level is carried out. The effect that different transformer connection types have on the propagation is studied through simulations. Many assumptions and simplifications had to be made due to several limiting factors during this work, mainly related to time and data restrictions.

The main result shows that when Delta – Wye Grounded and Wye – Wye Grounded transformers are used, the unbalance is halved when it passes to the turbine side. On the other hand, when Wye Grounded – Wye Grounded configuration was used, the unbalance was unaffected. The results also include a comparison of the use of different indices to quantify a voltage unbalance.

Place, publisher, year, edition, pages
2016.
Keyword [en]
voltage unbalance, wind power system, transformer connection, MATLAB/Simulink
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:uu:diva-318969OAI: oai:DiVA.org:uu-318969DiVA: diva2:1085633
External cooperation
Gotlands Energi AB
Educational program
Master Programme in Wind Power Project Management
Supervisors
Examiners
Available from: 2017-05-03 Created: 2017-03-29 Last updated: 2017-05-03Bibliographically approved

Open Access in DiVA

fulltext(1640 kB)33 downloads
File information
File name FULLTEXT01.pdfFile size 1640 kBChecksum SHA-512
ce00607e2dfcb7ef2964bae5d489b5480eabc9e76dffb5640881d4f685b473ebd31fe8d7e9b911a6e6746c688832aa84d3d4c74458c233a0677ea68277631031
Type fulltextMimetype application/pdf

By organisation
Department of Earth Sciences
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 33 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 237 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf