Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Analys av Lag 2014:266 ”Energikartläggning i stora företag” med efterföljande energikartläggning
KTH, School of Industrial Engineering and Management (ITM), Energy Technology.
2015 (Swedish)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesis
Abstract [sv]

EU har för avsikt att uppfylla 2020 målet om energianvändning och utsläpp. Som en del i detta försök så har flertalet olika åtgärder och lagar tagits fram. En av åtgärderna är att införa lag 2014:266 energikartläggning i stora företag som har sitt syfte i att minska stora företags energianvändning genom att belysa kostnadseffektiva åtgärdsförslag på verksamheten och dess fastigheter. Det här examensarbetet har riktat in sig mot lag 2014:266 för att dels sammanställa och analysera lagen och dels för att utföra en energikartläggning, i enlighet med lagen, på B-huset i Saab AB:s kontor Järfälla. Denna energikartläggning har utförts enligt de premisser som idag ställs av tillsynsmyndigheten, energimyndigheten. Slutligen har även, med Saab AB:s energikartläggning som grund, en analys om hur lag 2014:266 kommer att påverka stora företag när denna lag väl tas i drift. Energikartläggningen, se kapitel sex, har utförts helt i enlighet med energimyndighetens förslag på upplägg av energikartläggning och är en ”fristående” del i rapporten. Denna energikartläggning har visat att möjligheterna för energibesparing för B-huset är stor. Största besparingen som uppdagats avser ventilationen som idag har relativt dålig styrning och där maskinerna är gamla. Vidare tillkommer även andra åtgärdsförslag med en mindre besparingar som, liknande ventilationen, beror på att det inte finns full kontroll av husets styrsystem. Att stora företag i Sverige lagstadgas att utföra en energikartläggning anses enligt författaren positivt för energianvändningen då en energikartläggning med stor sannolikhet finner åtgärder som gör att företagen kan minska sina energikostnader. Anledningen till denna sänkning av energianvändning är att det ofta finns åtgärder som bygger på enklare åtgärder för fastigheten och dessa åtgärder är ofta helt utan, eller med en väldigt liten, investering.

Abstract [en]

EU has an intention to reach the 2020 goal about energy usage and emissions. As a part in this effort several different measures and laws have been introduced. One of the measures that has been implemented is the law 2014:266 “Energikartläggning i stora företag” (energy audit in large companies) which purpose is to reduce the amount of energy used by large companies by looking in to cost effective measuresThis master thesis targets the law 2014:266 in order to analyze the law, and also to perform an energy audit on house B in Saab AB:s office in Järfälla. This energy audit has been performed according to the premises compiled by the supervisory authority, the Swedish energy agency, so that the energy audit is as close as possible to the real one. Finally with the performed energy audit as background, an analysis on how the new law will affect the large companies has been performed.The performed energy audit, in chapter six, has been performed following the suggested approach from the Swedish energy agency and functions as an independent part of the report. This energy audit has reached the conclusion that there are great possibilities for energy savings in house B. The biggest energy saving is found in the ventilation that has poor controlling and were the machines are old. Other proposals for energy savings are made but with a smaller saving than the ventilation proposal, like improving the control on the heating system.That large companies are to perform, by law, an energy audit is seen as positive for the energy usage and it is regarded as a positive action because of the fact that energy audits will with high probability find measures that will reduce the energy usage. The reason for this energy usage reduction is that several of the measures are based on the fact that small measures can be done with no, or a small, investment.

Place, publisher, year, edition, pages
2015. , p. 49
National Category
Mechanical Engineering
Identifiers
URN: urn:nbn:se:kth:diva-200959OAI: oai:DiVA.org:kth-200959DiVA, id: diva2:1072116
External cooperation
Saab AB
Supervisors
Examiners
Available from: 2017-02-07 Created: 2017-02-07Bibliographically approved

Open Access in DiVA

fulltext(1062 kB)29 downloads
File information
File name FULLTEXT01.pdfFile size 1062 kBChecksum SHA-512
9731fb0dacef7ab809e1ed01d95d925afdc432fa6bf4fc1ea0313661853aed8fd9c8567ab97dcc3c0d58b497f3824991015c8d8c6c9559ce63fdf2caa30130e5
Type fulltextMimetype application/pdf

By organisation
Energy Technology
Mechanical Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 29 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 40 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf