Abstract

Fall accidents leads to an average of three deaths a day in Sweden. The high mortality and morbidity associated with falls among elderly is due to a high risk of falling caused by impaired mobility, sight and balance in combination with increased vulnerability as a result of fragile bones as well as comorbid conditions. Researchers at the department of Neuronics at KTH has developed a shock-absorbing floor that aim to reduce the risk of fall related fractures. The floors has shown promising results in mechanical drop tests but requires further analysis before it can be implemented in retirement homes.

The goal of this master thesis is to refine, adapt and validate the finite element model THUMS 4.02 for fall simulations. The model will then be used to analyze the shock absorbing ability of various floor systems. Model adaptations included modification of the material properties of the adipose tissue and cartilage in the hips and implantation of tied internal contacts. Validation was performed against data from two experimental studies selected in a literature study, dynamic impact with isolated pelvis and lateral hip impact of complete PMHS.

The experimental setups were reproduced in LS-Dyna and relatively close agreement for the force curves could be displayed in both cases. The model also showed realistic force response for fall simulations and a force reduction with up to 23% in simulation to the KTH developed floor system, differences could be seen for different fall positions of the model. Fall simulations agreed well with clinically and scientifically documented fracture loads and patterns. Further studies needs to be performed to further validate the model and analyze effect of different geometrical properties of floor system.

Place, publisher, year, edition, pages
2016. , 67 p.
Series
TRITA-STH, 2016:101
National Category
Medical Engineering
Identifiers
URN: urn:nbn:se:kth:diva-194412OAI: oai:DiVA.org:kth-194412DiVA: diva2:1040279
Educational program
Master of Science - Medical Engineering
Supervisors
Examiners
Available from: 2016-10-29 Created: 2016-10-27 Last updated: 2016-10-29Bibliographically approved

Open Access in DiVA

fulltext(2857 kB)18 downloads
File information
File name FULLTEXT01.pdfFile size 2857 kBChecksum SHA-512
72d67604193ff8a8821af090c0bb79835319a15ae808570871002c351b3f432ab0ddcb378c36f299d54c08d0cf7c2647e5c9de07604d48f4a0fcfcf44dba13a9
Type fulltextMimetype application/pdf

By organisation
School of Technology and Health (STH)
Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 18 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 36 hits
ReferencesLink to record
Permanent link

Direct link