Change search
ReferencesLink to record
Permanent link

Direct link
The zero flow performance of a sing-around type flow meter
1990 (English)In: Proceedings: IEEE 1990 Ultrasonics Symposium, December 4 - 7, 1990, Honolulu, HI, New York: IEEE Communications Society, 1990, Vol. 3, 1541-1544 p.Conference paper (Refereed)
Abstract [en]

Design considerations were taken to correct for the speed of sound influences and reciprocity effect. The meter was tested using from 1000 to 20000 sing-around loops. To investigate averaging phenomena, 1-100 primary velocity values were averaged to form one velocity value. The temperature range tested was 2-45°C, with measurements at 5°C intervals. The measurements show a zero flow stability of better than ±0.6 mm/s (±1 l/h, φ 25-mm pipe) in the entire temperature range. The standard deviation at each temperature tested was less than 0.45 mm/s. This implies that flow velocities as low as 6 cm/s (100 l/h, φ 25-mm pipe) could be measured with an accuracy of better than ±1%. The tests were made with water as the medium

Place, publisher, year, edition, pages
New York: IEEE Communications Society, 1990. Vol. 3, 1541-1544 p.
Research subject
Industrial Electronics
URN: urn:nbn:se:ltu:diva-31079DOI: 10.1109/ULTSYM.1990.171625Local ID: 5225b180-d8af-11db-a1bf-000ea68e967bISBN: 0-87942-562-8OAI: diva2:1004309
IEEE Ultrasonics Symposium : 04/12/1990 - 07/12/1990
Upprättat; 1990; 20070322 (pekkari)Available from: 2016-09-30 Created: 2016-09-30

Open Access in DiVA

fulltext(336 kB)0 downloads
File information
File name FULLTEXT01.pdfFile size 336 kBChecksum SHA-512
Type fulltextMimetype application/pdf

Other links

Publisher's full text

Search in DiVA

By author/editor
Delsing, Jerker

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

ReferencesLink to record