Expected performance of the superconducting submillimeter-wave limb emission sounder compared with aircraft data
Universität Bremen, Institute of Environmental Physics.
National Institute of Information and Communication Technology, Tokyo.
Universität Bremen, Institute of Environmental Physics.
Vise andre og tillknytning
2005 (engelsk)Inngår i: Radio Science, ISSN 0048-6604, E-ISSN 1944-799X, Vol. 40, nr 3, s. RS3016/1-RS3016/13Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The simulated retrieval performance of a submillimeter wave limb sounder was compared with that of an up-looking instrument with identical observation frequency bands and comparable noise temperature. The frequency bands were 624.32-626.32 and 649.12-650.32 GHz, and the retrieval simulations focused on the key trace gas species O-3, HCl, and ClO. As expected, the limb geometry leads to a better altitude resolution and larger measurement altitude range. The same retrieval setup was applied to measured spectra, taken by the up-looking Airborne Submillimeter Radiometer ( ASUR) instrument on 4 September 2002 at 19.11 degrees E, 71.90 degrees N and on 19 September 2002 at 44.10 degrees E, 4.10 degrees S. The observed structures in the fit residual near the HCl spectral lines at 625.9 GHz lead to the conclusion that the pressure shift parameter of HCl is likely to be higher than the value in the HITRAN spectroscopic database. Depending on the assumed temperature dependence of the shift, the HCl pressure shift value consistent with the ASUR data is 0.090-0.117 MHz/hPa instead of the 0.030 MHz/hPa reported in HITRAN. This result is in good agreement with very recent independent laboratory work which suggests a value of 0.110 MHz/hPa for the shift.

sted, utgiver, år, opplag, sider
2005. Vol. 40, nr 3, s. RS3016/1-RS3016/13
HSV kategori
Forskningsprogram
Rymdteknik
Identifikatorer
URN: urn:nbn:se:ltu:diva-9535Lokal ID: 82fb8e00-f8b3-11db-b2dd-000ea68e967bOAI: oai:DiVA.org:ltu-9535DiVA, id: diva2:982473
Merknad

Upprättat; 2005; 20070502 (pafi)

Tilgjengelig fra: 2016-09-29 Laget: 2016-09-29 Sist oppdatert: 2017-11-24bibliografisk kontrollert

Open Access i DiVA

fulltext(345 kB)37 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 345 kBChecksum SHA-512
44576f7d1003ba1b65ecb6c11eace3c6f3d83420ed1594c12b196462c9ae13bbfc7aa57c0a0ed11ccc858fa7b2042b967b3469d1f9426f06060d85084ea90e20
Type fulltextMimetype application/pdf

Søk i DiVA

Av forfatter/redaktør
Buehler, Stefan
I samme tidsskrift
Radio Science

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 37 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 97 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf