Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
The Level 2 research product algorithms for the Superconducting Submillimeter-Wave Limb-Emission Sounder (SMILES)
National Institute of Information and Communications Technology, 4-2-1 Nukui-kitamachi, Koganei.
Chalmers University of Technology.
National Institute of Information and Communications Technology, 4-2-1 Nukui-kitamachi, Koganei.
Chalmers University of Technology.
Vise andre og tillknytning
2011 (engelsk)Inngår i: Atmospheric Measurement Techniques, ISSN 1867-1381, E-ISSN 1867-8548, Vol. 4, 2105-2124 s.Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

This paper describes the algorithms of the level-2 research (L2r) processing chain developed for the Superconducting Submillimeter-Wave Limb-Emission Sounder (SMILES). The chain has been developed in parallel to the operational chain for conducting researches on calibration and retrieval algorithms. L2r chain products are available to the scientific community. The objective of version 2 is the retrieval of the vertical distribution of trace gases in the altitude range of 18–90 km. A theoretical error analysis is conducted to estimate the retrieval feasibility of key parameters of the processing: line-of-sight elevation tangent altitudes (or angles), temperature and ozone profiles. While pointing information is often retrieved from molecular oxygen lines, there is no oxygen line in the SMILES spectra, so the strong ozone line at 625.371 GHz has been chosen. The pointing parameters and the ozone profiles are retrieved from the line wings which are measured with high signal to noise ratio, whereas the temperature profile is retrieved from the optically thick line center. The main systematic component of the retrieval error was found to be the neglect of the non-linearity of the radiometric gain in the calibration procedure. This causes a temperature retrieval error of 5–10 K. Because of these large temperature errors, it is not possible to construct a reliable hydrostatic pressure profile. However, as a consequence of the retrieval of pointing parameters, pressure induced errors are significantly reduced if the retrieved trace gas profiles are represented on pressure levels instead of geometric altitude levels. Further, various setups of trace gas retrievals have been tested. The error analysis for the retrieved HOCl profile demonstrates that best results for inverting weak lines can be obtained by using narrow spectral windows.

sted, utgiver, år, opplag, sider
2011. Vol. 4, 2105-2124 s.
HSV kategori
Forskningsprogram
Rymdteknik
Identifikatorer
URN: urn:nbn:se:ltu:diva-4117DOI: 10.5194/amt-4-2105-2011Lokal ID: 1fefd9c4-e3b2-4ef4-8074-4cef9a50d4f0OAI: oai:DiVA.org:ltu-4117DiVA: diva2:976981
Merknad
Validerad; 2011; 20111217 (ysko)Tilgjengelig fra: 2016-09-29 Laget: 2016-09-29 Sist oppdatert: 2017-11-24bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler

Andre lenker

Forlagets fulltekst

Personposter BETA

Mendrok, Jana

Søk i DiVA

Av forfatter/redaktør
Mendrok, Jana
Av organisasjonen
I samme tidsskrift
Atmospheric Measurement Techniques

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 26 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf