Magnetic Resonance Imaging of the Heart: Image quality, measurement accuracy and patient experience
Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten.
2016 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

Background: Non-invasive diagnostic imaging of atherosclerotic coronary artery disease (CAD) is frequently carried out with cardiovascular magnetic resonance imaging (CMR) or myocardial perfusion single photon emission computed tomography (MPS). CMR is the gold standard for the evaluation of scar after myocardial infarction and MPS the clinical gold standard for ischemia. Magnetic Resonance Imaging (MRI) is at times difficult for patients and may induce anxiety while patient experience of MPS is largely unknown.

Aims: To evaluate image quality in CMR with respect to the sequences employed, the influence of atrial fibrillation, myocardial perfusion and the impact of patient information. Further, to study patient experience in relation to MRI with the goal of improving the care of these patients.

Method: Four study designs have been used. In paper I, experimental cross-over, paper (II) experimental controlled clinical trial, paper (III) psychometric crosssectional study and paper (IV) prospective intervention study. A total of 475 patients ≥ 18 years with primarily cardiac problems (I-IV) except for those referred for MRI of the spine (III) were included in the four studies.

Result: In patients (n=20) with atrial fibrillation, a single shot steady state free precession (SS-SSFP) sequence showed significantly better image quality than the standard segmented inversion recovery fast gradient echo (IR-FGRE) sequence (I). In first-pass perfusion imaging the gradient echo-echo planar imaging sequence (GREEPI) (n=30) had lower signal-to-noise and contrast–to-noise ratios than the steady state free precession sequence (SSFP) (n=30) but displayed a higher correlation with the MPS results, evaluated both qualitatively and quantitatively (II). The MRIAnxiety Questionnaire (MRI-AQ) was validated on patients, referred for MRI of either the spine (n=193) or the heart (n=54). The final instrument had 15 items divided in two factors regarding Anxiety and Relaxation. The instrument was found to have satisfactory psychometric properties (III). Patients who prior CMR viewed an information video scored significantly (lower) better in the factor Relaxation, than those who received standard information. Patients who underwent MPS scored lower on both factors, Anxiety and Relaxation. The extra video information had no effect on CMR image quality (IV).

Conclusion: Single shot imaging in atrial fibrillation produced images with less artefact than a segmented sequence. In first-pass perfusion imaging, the sequence GRE-EPI was superior to SSFP. A questionnaire depicting anxiety during MRI showed that video information prior to imaging helped patients relax but did not result in an improvement in image quality.

Ort, förlag, år, upplaga, sidor
Linköping: Linköping University Electronic Press, 2016. , s. 74
Serie
Linköping University Medical Dissertations, ISSN 0345-0082 ; 1524
Nationell ämneskategori
Radiologi och bildbehandling Medicinsk bildbehandling Kardiologi Medicinsk laboratorie- och mätteknik Allmänmedicin
Identifikatorer
URN: urn:nbn:se:liu:diva-130796DOI: 10.3384/diss.diva-130796ISBN: 9789176857427 (tryckt)OAI: oai:DiVA.org:liu-130796DiVA, id: diva2:955033
Disputation
2016-09-30, Originalet, Qulturum, Hus B4, Länssjukhuset Ryhov, Jönköping, 09:00 (Svenska)
Opponent
Handledare
Tillgänglig från: 2016-08-24 Skapad: 2016-08-24 Senast uppdaterad: 2018-01-10Bibliografiskt granskad
Delarbeten
1. Image quality and myocardial scar size determined with magnetic resonance imaging in patients with permanent atrial fibrillation: a comparison of two imaging protocols
Öppna denna publikation i ny flik eller fönster >>Image quality and myocardial scar size determined with magnetic resonance imaging in patients with permanent atrial fibrillation: a comparison of two imaging protocols
Visa övriga...
2010 (Engelska)Ingår i: CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, ISSN 1475-0961, Vol. 30, nr 2, s. 122-129Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Pandgt;Background: Magnetic resonance imaging (MRI) of the heart generally requires breath holding and a regular rhythm. Single shot 2D steady-state free precession (SS_SSFP) is a fast sequence insensitive to arrhythmia as well as breath holding. Our purpose was to determine image quality, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios and infarct size with a fast single shot and a standard segmented MRI sequence in patients with permanent atrial fibrillation and chronic myocardial infarction. Methods: Twenty patients with chronic myocardial infarction and ongoing atrial fibrillation were examined with inversion recovery SS_SSFP and segmented inversion recovery 2D fast gradient echo (IR_FGRE). Image quality was assessed in four categories: delineation of infarcted and non-infarcted myocardium, occurrence of artefacts and overall image quality. SNR and CNR were calculated. Myocardial volume (ml) and infarct size, expressed as volume (ml) and extent (%), were calculated, and the methodological error was assessed. Results: SS_SSFP had significantly better quality scores in all categories (P = 0 center dot 037, P = 0 center dot 014, P = 0 center dot 021, P = 0 center dot 03). SNRinfarct and SNRblood were significantly better for IR_FGRE than for SS_SSFP (P = 0 center dot 048, P = 0 center dot 018). No significant difference was found in SNRmyocardium and CNR. The myocardial volume was significantly larger with SS_SSFP (170 center dot 7 versus 159 center dot 2 ml, P andlt; 0 center dot 001), but no significant difference was found in infarct volume and infarct extent. Conclusion: SS_SSFP displayed significantly better image quality than IR_FGRE. The infarct size and the error in its determination were equal for both sequences, and the examination time was shorter with SS_SSFP.

Nyckelord
atrial fibrillation, magnetic resonance imaging, myocardial infarction, segmented inversion recovery 2D fast gradient echo, single shot inversion recovery 2D steady-state free precession
Nationell ämneskategori
Medicin och hälsovetenskap
Identifikatorer
urn:nbn:se:liu:diva-54159 (URN)10.1111/j.1475-097X.2009.00914.x (DOI)000274438800006 ()
Tillgänglig från: 2010-02-26 Skapad: 2010-02-26 Senast uppdaterad: 2016-08-24
2. An echo-planar imaging sequence is superior to a steady-state free precession sequence for visual as well as quantitative assessment of cardiac magnetic resonance stress perfusion
Öppna denna publikation i ny flik eller fönster >>An echo-planar imaging sequence is superior to a steady-state free precession sequence for visual as well as quantitative assessment of cardiac magnetic resonance stress perfusion
Visa övriga...
2017 (Engelska)Ingår i: Clinical Physiology and Functional Imaging, ISSN 1475-0961, E-ISSN 1475-097X, Vol. 37, nr 1, s. 52-61Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Background To assess myocardial perfusion, steady-state free precession cardiac magnetic resonance (SSFP, CMR) was compared with gradient-echo–echo-planar imaging (GRE-EPI) using myocardial perfusion scintigraphy (MPS) as reference. Methods Cardiac magnetic resonance perfusion was recorded in 30 patients with SSFP and in another 30 patients with GRE-EPI. Timing and extent of inflow delay to the myocardium was visually assessed. Signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were calculated. Myocardial scar was visualized with a phase-sensitive inversion recovery sequence (PSIR). All scar positive segments were considered pathologic. In MPS, stress and rest images were used as in clinical reporting. The CMR contrast wash-in slope was calculated and compared with the stress score from the MPS examination. CMR scar, CMR perfusion and MPS were assessed separately by one expert for each method who was blinded to other aspects of the study. Results Visual assessment of CMR had a sensitivity for the detection of an abnormal MPS at 78% (SSFP) versus 91% (GRE-EPI) and a specificity of 58% (SSFP) versus 84% (GRE-EPI). Kappa statistics for SSFP and MPS was 0·29, for GRE-EPI and MPS 0·72. The ANOVA of CMR perfusion slopes for all segments versus MPS score (four levels based on MPS) had correlation r = 0·64 (SSFP) and r = 0·96 (GRE-EPI). SNR was for normal segments 35·63 ± 11·80 (SSFP) and 17·98 ± 8·31 (GRE-EPI), while CNR was 28·79 ± 10·43 (SSFP) and 13·06 ± 7·61 (GRE-EPI). Conclusion GRE-EPI displayed higher agreement with the MPS results than SSFP despite significantly lower signal intensity, SNR and CNR.

Ort, förlag, år, upplaga, sidor
John Wiley & Sons, 2017
Nyckelord
cardiac imaging techniques, coronary heart disease, Magnetic Resonance Imaging, nuclear medicine, perfusion
Nationell ämneskategori
Radiologi och bildbehandling Medicinsk laboratorie- och mätteknik Medicinsk bildbehandling Klinisk medicin
Identifikatorer
urn:nbn:se:liu:diva-130795 (URN)10.1111/cpf.12267 (DOI)000390688200008 ()26147785 (PubMedID)
Anmärkning

Funding agencies: Medical Research Council of Southeast Sweden [12437]; Futurum, the County council of Jonkoping [12440, 81851, 217261]; Linkoping University; County Council of Ostergotland [281281]; Swedish Heart-Lung Foundation [20120449]

Tillgänglig från: 2016-08-24 Skapad: 2016-08-24 Senast uppdaterad: 2017-11-28Bibliografiskt granskad
3. Development and validation of a questionnaire evaluating patient anxiety during Magnetic Resonance Imaging: the Magnetic Resonance Imaging-Anxiety Questionnaire (MRI-AQ)
Öppna denna publikation i ny flik eller fönster >>Development and validation of a questionnaire evaluating patient anxiety during Magnetic Resonance Imaging: the Magnetic Resonance Imaging-Anxiety Questionnaire (MRI-AQ)
Visa övriga...
2016 (Engelska)Ingår i: Journal of Advanced Nursing, ISSN 0309-2402, E-ISSN 1365-2648, Vol. 72, nr 6, s. 1368-1380Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Aim. To develop and validate a new instrument measuring patient anxiety during Magnetic Resonance Imaging examinations, Magnetic Resonance Imaging-Anxiety Questionnaire. Background. Questionnaires measuring patients anxiety during Magnetic Resonance Imaging examinations have been the same as used in a wide range of conditions. To learn about patients experience during examination and to evaluate interventions, a specific questionnaire measuring patient anxiety during Magnetic Resonance Imaging is needed. Design. Psychometric cross-sectional study with test-retest design. Methods. A new questionnaire, Magnetic Resonance Imaging-Anxiety Questionnaire, was designed from patient expressions of anxiety in Magnetic Resonance Imaging-scanners. The sample was recruited between October 2012-October 2014. Factor structure was evaluated with exploratory factor analysis and internal consistency with Cronbachs alpha. Criterion-related validity, known-group validity and test-retest was calculated. Results. Patients referred for Magnetic Resonance Imaging of either the spine or the heart, were invited to participate. The development and validation of Magnetic Resonance Imaging-Anxiety Questionnaire resulted in 15 items consisting of two factors. Cronbachs alpha was found to be high. Magnetic Resonance Imaging-Anxiety Questionnaire correlated higher with instruments measuring anxiety than with depression scales. Known-group validity demonstrated a higher level of anxiety for patients undergoing Magnetic Resonance Imaging scan of the heart than for those examining the spine. Test-retest reliability demonstrated acceptable level for the scale. Conclusion. Magnetic Resonance Imaging-Anxiety Questionnaire bridges a gap among existing questionnaires, making it a simple and useful tool for measuring patient anxiety during Magnetic Resonance Imaging examinations.

Ort, förlag, år, upplaga, sidor
WILEY-BLACKWELL, 2016
Nyckelord
anxiety; instrument development; magnetic resonance imaging; nurse; nursing; reliability; validity
Nationell ämneskategori
Övrig annan medicin och hälsovetenskap
Identifikatorer
urn:nbn:se:liu:diva-129145 (URN)10.1111/jan.12917 (DOI)000376007400014 ()26893007 (PubMedID)
Anmärkning

Funding Agencies|Swedish Heart and Lung Foundation; Futurum County Council of Jonkoping

Tillgänglig från: 2016-06-13 Skapad: 2016-06-13 Senast uppdaterad: 2017-11-28

Open Access i DiVA

Magnetic Resonance Imaging of the Heart: Image quality, measurement accuracy and patient experience(1483 kB)226 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 1483 kBChecksumma SHA-512
a13cbaf62bd9498696687c6588eb8b72cbb80694093f800a214fa991261e9144373e357442242c286d411b9cfcc5af8c5dc97dd0973189b32f1df78609158e7f
Typ fulltextMimetyp application/pdf
omslag(361 kB)31 nedladdningar
Filinformation
Filnamn COVER01.pdfFilstorlek 361 kBChecksumma SHA-512
dffe0af4f54f3f86f1c4111d7fb23c8af4df6a82a05a2e9232b88a09a903cb66edc42c48bf630a90030b6c6e13fce497c08a45f03941e219fa731194dc3e912c
Typ coverMimetyp application/pdf

Övriga länkar

Förlagets fulltext

Sök vidare i DiVA

Av författaren/redaktören
Ahlander, Britt-Marie
Av organisationen
Avdelningen för kardiovaskulär medicinMedicinska fakulteten
Radiologi och bildbehandlingMedicinsk bildbehandlingKardiologiMedicinsk laboratorie- och mätteknikAllmänmedicin

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 226 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
isbn
urn-nbn

Altmetricpoäng

doi
isbn
urn-nbn
Totalt: 1317 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf