Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Noise Removal with Maintained Spatial Resolution in Raman Images of Cells Exposed to Submicron Polystyrene Particles
Swedish Def Res Agcy, FOI, Cementvagen 20, SE-90182 Umea, Sweden..
Swedish Def Res Agcy, FOI, Cementvagen 20, SE-90182 Umea, Sweden..
Swedish Def Res Agcy, FOI, Cementvagen 20, SE-90182 Umea, Sweden..
Swedish Univ Agr Sci, Dept Forest Biomat & Technol, SE-90183 Umea, Sweden..
Visa övriga samt affilieringar
2016 (Engelska)Ingår i: NANOMATERIALS, ISSN 2079-4991, Vol. 6, nr 5, artikel-id UNSP 83Artikel i tidskrift (Refereegranskat) Published
Resurstyp
Text
Abstract [en]

The biodistribution of 300 nm polystyrene particles in A549 lung epithelial cells has been studied with confocal Raman spectroscopy. This is a label-free method in which particles and cells can be imaged without using dyes or fluorescent labels. The main drawback with Raman imaging is the comparatively low spatial resolution, which is aggravated in heterogeneous systems such as biological samples, which in addition often require long measurement times because of their weak Raman signal. Long measurement times may however induce laser-induced damage. In this study we use a super-resolution algorithm with Tikhonov regularization, intended to improve the image quality without demanding an increased number of collected pixels. Images of cells exposed to polystyrene particles have been acquired with two different step lengths, i.e., the distance between pixels, and compared to each other and to corresponding images treated with the super-resolution algorithm. It is shown that the resolution after application of super-resolution algorithms is not significantly improved compared to the theoretical limit for optical microscopy. However, to reduce noise and artefacts in the hyperspectral Raman images while maintaining the spatial resolution, we show that it is advantageous to use short mapping step lengths and super-resolution algorithms with appropriate regularization. The proposed methodology should be generally applicable for Raman imaging of biological samples and other photo-sensitive samples.

Ort, förlag, år, upplaga, sidor
2016. Vol. 6, nr 5, artikel-id UNSP 83
Nyckelord [en]
Raman spectroscopy, Raman imaging, super-resolution, particles, cells, Tikhonov regularization
Nationell ämneskategori
Radiologi och bildbehandling Teknik och teknologier
Identifikatorer
URN: urn:nbn:se:uu:diva-299922DOI: 10.3390/nano6050083ISI: 000378805500003OAI: oai:DiVA.org:uu-299922DiVA, id: diva2:950343
Tillgänglig från: 2016-07-29 Skapad: 2016-07-29 Senast uppdaterad: 2016-08-19Bibliografiskt granskad

Open Access i DiVA

fulltext(1770 kB)282 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 1770 kBChecksumma SHA-512
30cf4a5b4663dd67621999d11dadb733323b14b9be0a2609dbaf3d8e685a1c3506a8044ec01ea907e04ee1ba0d0b931299ab05937ec93d7ea02105161a52a23e
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltext

Sök vidare i DiVA

Av författaren/redaktören
Österlund, Lars
Av organisationen
Fasta tillståndets fysik
Radiologi och bildbehandlingTeknik och teknologier

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 282 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 1192 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf