Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Swedish randomized controlled trial of cardiotocography only versus cardiotocography plus ST analysis of fetal electrocardiogram revisited: analysis of data according to standard versus modified intention-to-treat principle.
Visa övriga samt affilieringar
2011 (Engelska)Ingår i: Acta Obstetricia et Gynecologica Scandinavica, ISSN 0001-6349, E-ISSN 1600-0412, ISSN 0001-6349, Vol. 90, nr 9, s. 990-996Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

OBJECTIVE: To undertake a renewed analysis of data from the previously published Swedish randomized controlled trial on intrapartum fetal monitoring with cardiotocography (CTG-only) vs. CTG plus ST analysis of fetal electrocardiogram (CTG+ST), using current standards of intention-to-treat (ITT) analysis and to compare the results with those of the modified ITT (mITT) and per protocol analyses. METHODS: Renewed extraction of data from the original database including all cases randomized according to primary case allocation (n=5 049). MAIN OUTCOME MEASURE: Metabolic acidosis in umbilical artery at birth (pH <7.05, base deficit in extracellular fluid >12.0 mmol/l) including samples of umbilical vein blood or neonatal blood if umbilical artery blood was missing. RESULTS: The metabolic acidosis rates were 0.66% (17 of 2 565) and 1.33% (33 of 2 484) in the CTG+ST and CTG-only groups, respectively [relative risk (RR) 0.50; 95% confidence interval (CI) 0.28-0.88; p=0.019]. The original mITT gave RR 0.47, 95%CI 0.25-0.86 (p=0.015), mITT with correction for 10 previously misclassified cases RR 0.48, 95%CI 0.24-0.96 (p=0.038) and per protocol analysis RR 0.40, 95%CI 0.20-0.80 (p=0.009). The level of significance of the difference in metabolic acidosis rates between the two groups remained unchanged in all analyses. CONCLUSION: Re-analysis of data according to the ITT principle showed that regardless of the method of analysis, the Swedish randomized controlled trial maintained its ability to demonstrate a significant reduction in metabolic acidosis rate when using CTG+ST analysis for fetal surveillance in labor.

Ort, förlag, år, upplaga, sidor
John Wiley & Sons Ltd. , 2011. Vol. 90, nr 9, s. 990-996
Nyckelord [en]
randomized controlled trial, cardiotocography/methods, delivery, obstetric/methods, electrocardiography, female, heart rate, humans, fetal, intention, intention to treat analysis, labor, pregnancy, obstetric, pregnancy outcome, sweden, Medicinteknik
Nationell ämneskategori
Biomedicinsk laboratorievetenskap/teknologi
Identifikatorer
URN: urn:nbn:se:hb:diva-1215DOI: 10.1111/j.1600-0412.2011.01203.xLokalt ID: 2320/10158OAI: oai:DiVA.org:hb-1215DiVA, id: diva2:869239
Tillgänglig från: 2015-11-13 Skapad: 2015-11-13 Senast uppdaterad: 2017-09-04Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Sök vidare i DiVA

Av författaren/redaktören
Rosén, Karl Gustaf
Av organisationen
Institutionen Ingenjörshögskolan
I samma tidskrift
Acta Obstetricia et Gynecologica Scandinavica
Biomedicinsk laboratorievetenskap/teknologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 488 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf