Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
A smart catheter system for minimally invasive brain monitoring
KTH, Skolan för informations- och kommunikationsteknik (ICT), Industriell och Medicinsk Elektronik. KTH, Skolan för informations- och kommunikationsteknik (ICT), Centra, VinnExcellence Center for Intelligence in Paper and Packaging, iPACK.
KTH, Skolan för informations- och kommunikationsteknik (ICT), Industriell och Medicinsk Elektronik. KTH, Skolan för informations- och kommunikationsteknik (ICT), Centra, VinnExcellence Center for Intelligence in Paper and Packaging, iPACK.
Vise andre og tillknytning
2015 (engelsk)Inngår i: Proceedings of the International Conference on Biomedical Electronics and Devices, SciTePress, 2015, s. 198-203Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

This paper demonstrates a smart catheter system with intracranial pressure (ICP) and temperature sensing capability which is designed for real-time monitoring in traumatic brain injury (TBI) therapy. It uses a single flexible catheter with a 1 mm (3 Fr) diameter that integrates electrodes and sophisticated silicon chip on flexible substrates, enabling multimodality monitoring of physiological signals. A micro-electromechanical-system (MEMS) catheter pressure sensor is mounted on the distal end. It can be used for detecting both pressure and temperature by different switch configurations, which minimizes the size of catheter and reduces the cost. The interconnects (signalling conductors) are printed on a bio-compatible flexible substrate, and the sensor is interfaced with an embedded electronic system at the far-end. The electronic system consists of analog front end with analog-to-digital converter (ADC), a microcontroller, and data interface to the hospital infrastructure with a graphical user interface (GUI). The overall smart catheter system achieves a pressure sensing root mean square error (RMSE) of ±1.5 mmHg measured from 20 mmHg to 300 mmHg above 1 atm and a temperature sensing RMSE of ±0.08°C measured from 32°C to 42°C. The sampling rate can be up to 10S/s. The in vivo performance is demonstrated in laboratory animals.

sted, utgiver, år, opplag, sider
SciTePress, 2015. s. 198-203
Emneord [en]
Pressure, Real-time monitoring, Smart catheter, TBI, Temperature
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-174732DOI: 10.5220/0005285501980203ISI: 000380546700031Scopus ID: 2-s2.0-84936803084ISBN: 978-989-758-071-0 (tryckt)OAI: oai:DiVA.org:kth-174732DiVA, id: diva2:860882
Konferanse
8th International Conference on Biomedical Electronics and Devices, BIODEVICES 2015; Lisbon; Portugal
Merknad

QC 20151014. QC 20160212

Tilgjengelig fra: 2015-10-14 Laget: 2015-10-07 Sist oppdatert: 2016-09-05bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Søk i DiVA

Av forfatter/redaktør
Zou, ZhuoZhai, ChuanyingTenhunen, HannuZheng, Lirong
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric

doi
isbn
urn-nbn
Totalt: 574 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf