Digitala Vetenskapliga Arkivet

Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Modellering och implementering av simultan dubbel gradient kromatografi
KTH, Skolan för kemivetenskap (CHE).
2015 (svensk)Independent thesis Advanced level (degree of Master (Two Years)), 20 poäng / 30 hpOppgaveAlternativ tittel
Modeling and Implementation of Simultaneous Double Gradient Chromatography (engelsk)
Abstract [en]

Polypeptides are becoming an important component of the antibiotic therapeutics. The production demand of therapeutic polypeptides is increasing and there is a significant interest in developing more efficient production processes. In pharmaceutical industries, polypeptides are produced as a crude mixture. Reverse phase high performance liquid chromatography (RP HPLC) is used as a typical separation technique to purify the target polypeptide from other impurities. Currently organic modifier gradients are used to elute product peptides separately from impurities. In this work, we add a second, simultaneous counter-ion gradient, in the hope of increasing separation performance and call it double gradient reverse phase chromatography. A general procedure of the model-based optimization of a polypeptide crude mixture purification process was followed to evaluate the effects of the double gradients on industrial chromatographic process. The target polypeptide elution profile was modeled with a bi-Langmuir adsorption equilibrium isotherm. The isotherm parameters of the target polypeptide were estimated by the inverse method. The model parameters of the impurities were regressed from experimental data. The variations of the isotherm parameters with the modifier concentration and counter-ion concentration were taken into account of the adsorption model. After model calibration and validation by comparison with suitable experimental data, Pareto optimization of the process were carried out to analyze the differences between single gradient chromatography and double gradient chromatography. It was observed that the additional linear gradient of counter-ion concentration did not improve the separation process. Conclusively we were able to demonstrate the concept of double gradient reverse phase chromatography within limited time and possible least experimental efforts.

sted, utgiver, år, opplag, sider
2015. , s. 65
Emneord [en]
Chromatography, peptides, pharmaceuticals, process modeling, Paretooptimization
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-172447OAI: oai:DiVA.org:kth-172447DiVA, id: diva2:848270
Tilgjengelig fra: 2015-08-24 Laget: 2015-08-24 Sist oppdatert: 2022-06-23bibliografisk kontrollert

Open Access i DiVA

fulltext(1811 kB)563 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 1811 kBChecksum SHA-512
bd77a729f3ab4b9f580911c0da8f1deda881e8a2636dbe262413323100523d6f0760930db50aa6b05747c3a47d2c9ffab32720bf94fd9e2c7d0580f28e6346b8
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 563 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 1383 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf