Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Optimisation of quantitative lung SPECT applied to mild COPD: a software phantom simulation study
Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för radiologiska vetenskaper. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Centrum för kirurgi, ortopedi och cancervård, Radiofysikavdelningen US.ORCID-id: 0000-0002-1380-2497
Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för radiologiska vetenskaper. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för radiologiska vetenskaper. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Östergötlands Läns Landsting, Centrum för kirurgi, ortopedi och cancervård, Radiofysikavdelningen US.ORCID-id: 0000-0003-0209-498X
Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för radiologiska vetenskaper. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Östergötlands Läns Landsting, Centrum för kirurgi, ortopedi och cancervård, Radiofysikavdelningen US.ORCID-id: 0000-0003-3352-8330
Vise andre og tillknytning
2015 (engelsk)Inngår i: EJNMMI research, ISSN 2191-219X, Vol. 5, nr 16Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

BACKGROUND: The amount of inhomogeneities in a (99m)Tc Technegas single-photon emission computed tomography (SPECT) lung image, caused by reduced ventilation in lung regions affected by chronic obstructive pulmonary disease (COPD), is correlated to disease advancement. A quantitative analysis method, the CVT method, measuring these inhomogeneities was proposed in earlier work. To detect mild COPD, which is a difficult task, optimised parameter values are needed.

METHODS: In this work, the CVT method was optimised with respect to the parameter values of acquisition, reconstruction and analysis. The ordered subset expectation maximisation (OSEM) algorithm was used for reconstructing the lung SPECT images. As a first step towards clinical application of the CVT method in detecting mild COPD, this study was based on simulated SPECT images of an advanced anthropomorphic lung software phantom including respiratory and cardiac motion, where the mild COPD lung had an overall ventilation reduction of 5%.

RESULTS: The best separation between healthy and mild COPD lung images as determined using the CVT measure of ventilation inhomogeneity and 125 MBq (99m)Tc was obtained using a low-energy high-resolution collimator (LEHR) and a power 6 Butterworth post-filter with a cutoff frequency of 0.6 to 0.7 cm(-1). Sixty-four reconstruction updates and a small kernel size should be used when the whole lung is analysed, and for the reduced lung a greater number of updates and a larger kernel size are needed.

CONCLUSIONS: A LEHR collimator and 125 (99m)Tc MBq together with an optimal combination of cutoff frequency, number of updates and kernel size, gave the best result. Suboptimal selections of either cutoff frequency, number of updates and kernel size will reduce the imaging system's ability to detect mild COPD in the lung phantom.

sted, utgiver, år, opplag, sider
2015. Vol. 5, nr 16
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-117857DOI: 10.1186/s13550-015-0086-2ISI: 000358130300001PubMedID: 25853022OAI: oai:DiVA.org:liu-117857DiVA, id: diva2:811406
Tilgjengelig fra: 2015-05-12 Laget: 2015-05-12 Sist oppdatert: 2016-04-24

Open Access i DiVA

fulltext(923 kB)296 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 923 kBChecksum SHA-512
ae1fdf98822df3a39d0b4558c19a2bcc20f52b5d03f1c387f124b33e903898417bd43528324ba50a7c4a7ca4fdf23df91069046bb249ec15e78a4a146b6b866b
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstPubMed

Søk i DiVA

Av forfatter/redaktør
Norberg, PernillaOlsson, AnnaAlm Carlsson, GudrunSandborg, MichaelGustafsson, Agneta
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 296 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 184 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf