Discrimination and Quantification of Volatile Organic Compounds in the ppb-Range with Gas Sensitive SiC-FETs Using Multivariate Statistics
Linköpings universitet, Institutionen för fysik, kemi och biologi, Tillämpad sensorvetenskap. Linköpings universitet, Tekniska fakulteten. Saarland University, Lab for Measurement Technology, Germany. (Applied Sensor Science)
Saarland University, Lab for Measurement Technology, Germany.
Linköpings universitet, Institutionen för fysik, kemi och biologi, Tillämpad sensorvetenskap. Linköpings universitet, Tekniska fakulteten. (Applied Sensor Science)
Saarland University, Germany. (Lab for Measurement Technology)
Vise andre og tillknytning
2015 (engelsk)Inngår i: Sensors and actuators. B, Chemical, ISSN 0925-4005, E-ISSN 1873-3077, Vol. 214, s. 225-233Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Gas sensitive field effect transistors based on silicon carbide, SiC-FETs, have been studied for indoor air quality applications. The selectivity of the sensors was increased by temperature cycled operation, TCO, and data evaluation based on multivariate statistics. Discrimination of benzene, naphthalene, and formaldehyde independent of the level of background humidity is possible by using shape describing features as input for Linear Discriminant Analysis, LDA, or Partial Least Squares – Discriminant Analysis, PLS-DA. Leave-one-out cross-validation leads to a correct classification rate of 90 % for LDA, and for PLS-DA a classification rate of 83 % is achieved. Quantification of naphthalene in the relevant concentration range, i.e. 0 ppb to 40 ppb, was performed by Partial Least Squares Regression and a combination of LDA with a second order polynomial fit function. The resolution of the model based on a calibration with three concentrations was approximately 8 ppb at 40 ppb naphthalene for both algorithms.

Hence, the suggested strategy is suitable for on demand ventilation control in indoor air quality application systems.

sted, utgiver, år, opplag, sider
Elsevier, 2015. Vol. 214, s. 225-233
Emneord [en]
Indoor Air Quality, temperature modulation, Linear Discriminant Analysis, Partial Least Squares, trace level detection
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-115560DOI: 10.1016/j.snb.2015.03.016ISI: 000353131300031OAI: oai:DiVA.org:liu-115560DiVA, id: diva2:795538
Prosjekter
SENSIndoor
Forskningsfinansiär
EU, FP7, Seventh Framework Programme, 604311Tilgjengelig fra: 2015-03-16 Laget: 2015-03-16 Sist oppdatert: 2017-12-04

Open Access i DiVA

fulltext(790 kB)125 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 790 kBChecksum SHA-512
8309891a27fe15bbd95c889b0132c50d58fd1ab0ffdcd85e594fdd4d86494dcc416696415f71d43935bf83a57947c44a606cdac376d7777c266d669b79858de8
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fullteksthttp://dx.doi.org/10.1016/j.snb.2015.03.016

Søk i DiVA

Av forfatter/redaktør
Bur, ChristianPuglisi, DonatellaLloyd Spetz, AnitaAndersson, Mike
Av organisasjonen
I samme tidsskrift
Sensors and actuators. B, Chemical

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 125 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 495 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf