Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Fast-Neutron Tomography using a Mobile Neutron Generator for Assessment of Steam-Water Distributions in Two-Phase Flows
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Fysiska sektionen, Institutionen för fysik och astronomi, Tillämpad kärnfysik.ORCID-id: 0000-0001-7370-6539
2014 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

This thesis describes the measurement technique of fast-neutron tomography for assessing spatial distributions of steam and water in two-phase flows. This so-called void distribution is of importance both for safe operation and for efficient use of the fuel in light water reactors, which compose the majority of the world’s commercial nuclear reactors. The technique is aimed for usage at thermal-hydraulic test loops, where heated two-phase flows are being investigated under reactor-relevant conditions.

By deploying portable neutron generators in transmission tomography, the technique becomes applicable to stationary objects, such as thermal-hydraulic test loops. Fast neutrons have the advantage of high transmission through metallic structures while simultaneously being relatively sensitive to the water/void content. However, there are also challenges, such as the relatively low yield of commercially available fast-neutron generators, the tendency of fast neutrons to scatter in the interactions with materials and the relatively low efficiency encountered in fast-neutron detection.

The thesis describes the design of a prototype instrument, FANTOM, which has been assembled and demonstrated. The main design parameters have been optimized to achieve maximal signal count rate in the detector elements, while simultaneously reaching an image unsharpness of ≤0.5 mm. Radiographic projections recorded with the assembled instrument are presented, and the performance parameters of FANTOM are deduced.

Furthermore, tomographic reconstruction methods for axially symmetric objects, which is relevant for some test loops, have been developed and demonstrated on measured data from three test objects. The attenuation distribution was reconstructed with a radial resolution of 0.5 mm and an RMS error of 0.02 cm-1, based on data recorded using an effective measurement time of 3.5 hours per object. For a thermal-hydraulic test loop, this can give a useful indication of the flow mode, but further development is desired to improve the precision of the measurements.

Instrument upgrades are foreseen by introducing a more powerful neutron generator and by adding detector elements, speeding up the data collection by several orders of magnitude and allowing for higher precision data. The requirements and performance of an instrument for assessment of arbitrary non-symmetric test loops is discussed, based on simulations.

Ort, förlag, år, upplaga, sidor
Uppsala: Acta Universitatis Upsaliensis, 2014. , s. 70
Serie
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology, ISSN 1651-6214 ; 1146
Nyckelord [en]
Void distribution, neutron tomography, plastic scintillator, transmission measurements, neutron detection
Nationell ämneskategori
Fysik
Forskningsämne
Tillämpad kärnfysik
Identifikatorer
URN: urn:nbn:se:uu:diva-222459ISBN: 978-91-554-8947-2 (tryckt)OAI: oai:DiVA.org:uu-222459DiVA, id: diva2:711662
Disputation
2014-06-04, Polhemsalen, Ångströmlaboratoriet, Lägerhyddsvägen 1, Uppsala, 09:15 (Engelska)
Opponent
Handledare
Tillgänglig från: 2014-05-12 Skapad: 2014-04-10 Senast uppdaterad: 2017-05-05Bibliografiskt granskad
Delarbeten
1. Effects of proton escape on detection efficiency in thin scintillator elements and its consequences for optimization of fast-neutron imaging
Öppna denna publikation i ny flik eller fönster >>Effects of proton escape on detection efficiency in thin scintillator elements and its consequences for optimization of fast-neutron imaging
2011 (Engelska)Ingår i: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, ISSN 0168-9002, E-ISSN 1872-9576, Vol. 651, nr 1, s. 110-116Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Plastic scintillators are commonly used for neutron detection in the MeV energy range, based on n–p scattering and the subsequent deposition of recoil proton's kinetic energy in the detector material. This detection procedure gives a quasi-rectangular energy deposition distribution for mono-energetic neutrons, extending from zero to the neutron energy. However, if the detector sensitive element (DSE) is small, the energy deposition may be incomplete due to the recoil proton escape.

In the application of neutron imaging, here exemplified by fast-neutron tomography, two conflicting requirements have been identified: (1) thin DSEs are required to obtain high spatial resolution and (2) energy discrimination may be required to reduce the influence of neutrons being scattered into the DSEs, which generally occurs at lower energies. However, at small DSE widths, the reduction of energy deposition due to recoil proton escape may cause a significant decrease in detection efficiency when energy discrimination is applied.

In this work, energy deposition distributions in small-size DSEs have been simulated for Deuterium–Deuterium (DD; 2.5 MeV) and Deuterium–Tritium (DT; 14.1 MeV) fusion neutrons. The intrinsic efficiency has been analyzed as a function of energy discrimination level for various detector widths. The investigations show that proton recoil escape causes a significant drop in intrinsic detection efficiency for thin DSEs. For DT neutrons, the drop is 10% at a width of 3.2 mm and 50% at a width of 0.6 mm, assuming an energy threshold at half the incident neutron energy. The corresponding widths for a DD detector are 0.17 and 0.03 mm, respectively.

Finally, implications of the proton escape effect on the design of a fast-neutron tomography device for void distribution measurements at Uppsala University are presented. It is shown that the selection of DSE width strongly affects the instrument design when optimizing for image unsharpness.

Nyckelord
Neutron tomography, plastic scintillator, neutron detector, Neutron imaging, Recoil protonescape, Edge effects
Nationell ämneskategori
Fysik
Forskningsämne
Tillämpad kärnfysik; Fysik med inriktning mot tillämpad kärnfysik
Identifikatorer
urn:nbn:se:uu:diva-146195 (URN)10.1016/j.nima.2011.01.002 (DOI)000295437900024 ()
Projekt
STUNT
Tillgänglig från: 2011-02-15 Skapad: 2011-02-15 Senast uppdaterad: 2017-12-11Bibliografiskt granskad
2. Correction for dynamic bias error in transmission measurements of void fraction
Öppna denna publikation i ny flik eller fönster >>Correction for dynamic bias error in transmission measurements of void fraction
2012 (Engelska)Ingår i: Review of Scientific Instruments, ISSN 0034-6748, E-ISSN 1089-7623, Vol. 83, nr 12, s. 125110-Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Dynamic bias errors occur in transmission measurements, such as X-ray, gamma, or neutron radiography or tomography. This is observed when the properties of the object are not stationary in time and its average properties are assessed. The nonlinear measurement response to changes in transmission within the time scale of the measurement implies a bias, which can be difficult to correct for. A typical example is the tomographic or radiographic mapping of void content in dynamic two-phase flow systems. In this work, the dynamic bias error is described and a method to make a first-order correction is derived. A prerequisite for this method is variance estimates of the system dynamics, which can be obtained using high-speed, time-resolved data acquisition. However, in the absence of such acquisition, a priori knowledge might be used to substitute the time resolved data. Using synthetic data, a void fraction measurement case study has been simulated to demonstrate the performance of the suggested method. The transmission length of the radiation in the object under study and the type of fluctuation of the void fraction have been varied. Significant decreases in the dynamic bias error were achieved to the expense of marginal decreases in precision.

Nyckelord
error correction; fission reactor cooling; flow measurement; light water reactors; measurement errors; two-phase flow
Nationell ämneskategori
Annan fysik
Identifikatorer
urn:nbn:se:uu:diva-189683 (URN)10.1063/1.4772704 (DOI)000312834300066 ()
Tillgänglig från: 2013-01-04 Skapad: 2013-01-03 Senast uppdaterad: 2017-12-06Bibliografiskt granskad
3. Design and initial 1D radiography tests of the FANTOM mobile fast-neutron radiography and tomography system
Öppna denna publikation i ny flik eller fönster >>Design and initial 1D radiography tests of the FANTOM mobile fast-neutron radiography and tomography system
Visa övriga...
2014 (Engelska)Ingår i: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, ISSN 0168-9002, E-ISSN 1872-9576, Vol. 756, s. 82-93Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The FANTOM system is a tabletop sized fast-neutron radiography and tomography system newly developed at the Applied Nuclear Physics Division of Uppsala University. The main purpose of the system is to provide time-averaged steam-and-water distribution measurement capability inside the metallic structures of two-phase test loops for Light Water Reactor thermal-hydraulic studies using a portable fusion neutron generator. The FANTOM system provides a set of 1D neutron transmission data, which may be inserted into tomographic reconstruction algorithms to achieve a 2D mapping of the steam-and-water distribution.

 

In this paper, the selected design of FANTOM is described and motivated. The detector concept is based on plastic scintillator elements, separated for spatial resolution. Analysis of pulse heights on an event-to-event basis is used for energy discrimination. Although the concept allows for close stacking of a large number of detector elements, this demonstrator is equipped with only three elements in the detector and one additional element for monitoring the yield from the neutron generator.

 

The first measured projections on test objects of known configurations are presented. These were collected using a Sodern Genie 16 neutron generator with an isotropic yield of about 1E8 neutrons per second, and allowed for characterization of the instrument’s capabilities. At an energy threshold of 10 MeV, the detector offered a count rate of about 500 cps per detector element. The performance in terms of spatial resolution was validated by fitting a Gaussian Line Spread Function to the experimental data, a procedure that revealed a spatial unsharpness in good agreement with the predicted FWHM of 0.5 mm.

Nationell ämneskategori
Fysik
Identifikatorer
urn:nbn:se:uu:diva-221262 (URN)10.1016/j.nima.2014.04.052 (DOI)000338347800013 ()
Tillgänglig från: 2014-03-27 Skapad: 2014-03-27 Senast uppdaterad: 2017-12-05Bibliografiskt granskad
4. Neutron tomography of axially symmetric objects using 14 MeV neutrons from a portable neutron generator
Öppna denna publikation i ny flik eller fönster >>Neutron tomography of axially symmetric objects using 14 MeV neutrons from a portable neutron generator
2014 (Engelska)Ingår i: Review of Scientific Instruments, ISSN 0034-6748, E-ISSN 1089-7623, Vol. 85, nr 8, s. 085109-Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

In nuclear boiling water reactor cores, the distribution of water and steam (void) is essential for both safety and efficiency reasons. In order to enhance predictive capabilities, void distribution assessment is performed in two-phase test-loops under reactor-relevant conditions. This article proposes the novel technique of fast-neutron tomography using a portable deuterium-tritium neutron generator to determine the void distribution in these loops.Fast neutrons have the advantage of high transmission through the metallic structures and pipes typically concealing a thermal-hydraulic test loop, while still being fairly sensitive to the water/void content. However, commercially available fast-neutron generators also have the disadvantage of a relatively low yield and fast-neutron detection also suffers from relatively low detection efficiency. Fortunately, some loops are axially symmetric, a property which can be exploited to reduce the amount of data needed for tomographic measurement, thus limiting the interrogation time needed.In this article, three axially-symmetric test objects depicting a thermal-hydraulic test loop have been examined; steel pipes with outer diameter 24 mm, thickness 1.5 mm and with three different distributions of the plastic material POM inside the pipes. Data recorded with the FANTOM fast-neutron tomography instrument have been used to perform tomographic reconstructions to assess their radial material distribution. Here, a dedicated tomographic algorithm that exploits the symmetry of these objects has been applied, which is described in the paper.Results are demonstrated in 20 rixel (radial pixel) reconstructions of the interior constitution and 2D visualization of the pipe interior is demonstrated. The local POM attenuation coefficients in the rixels were measured with errors (RMS) of 0.025, 0.020 and 0.022 cm-1, solid POM attenuation coefficient. The accuracy and precision is high enough to provide a useful indication on the flow mode, and a visualization of the radial material distribution can be obtained. A benefit of this system is its potential to be mounted at any axial height of a two-phase test section without requirements for pre-fabricated entrances or windows. This could mean a significant increase in flexibility of the void distribution assessment capability at many existing two-phase test loops.

Nationell ämneskategori
Fysik
Identifikatorer
urn:nbn:se:uu:diva-220825 (URN)10.1063/1.4890662 (DOI)000342913500076 ()
Tillgänglig från: 2014-03-20 Skapad: 2014-03-20 Senast uppdaterad: 2017-12-05Bibliografiskt granskad

Open Access i DiVA

fulltext(13242 kB)1259 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 13242 kBChecksumma SHA-512
603ba30fa348ddcec5d8a6034769ac900af1a8a219b6b2428ae7f4dcf3e7e12dd05c2dba1c727ec3fa58e045d692f9f4a7a9ddf3960a449542ae42d452f26cae
Typ fulltextMimetyp application/pdf
Köp publikationen >>

Sök vidare i DiVA

Av författaren/redaktören
Andersson, Peter
Av organisationen
Tillämpad kärnfysik
Fysik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 1259 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

isbn
urn-nbn

Altmetricpoäng

isbn
urn-nbn
Totalt: 2295 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf