Estimated Droop Control for Parallel Connected Voltage Source Inverters: Stability Enhancement
Karlstad University, Faculty of Technology and Science, Department of Physics and Electrical Engineering.
2013 (English)Independent thesis Advanced level (degree of Master (One Year)), 10 credits / 15 HE creditsStudent thesis
Abstract [en]

Renewable Energy Sources (RES) are considered as the replacement of conventionalenergy sources. These RES can use wind energy, solar light, bio waste and can alsobe in the form of small hydro power units. These RES has very poor power qualityand contains voltage uctuations and variable frequency. These factors make RES astability risk for the main utility grid. As a solution, currently inverters with dierentdesign techniques are being used as an interface between RES and main utility grid. Thecurrent study proposed a new technique "estimated droop control" for inverter design.The conventional droop control technique which was already used in inverter design, hasdiculty in synchronizing parallel connected inverters with dierent droop gains and lineimpedances. The proposed "estimated droop control" does not use any predened droopvalues for inverters and all inverters are responsible for the estimation of their own droopvalues with respect to their output power. Therefore, inverters are not bound to usesame and static droop values which are considered as a vital communication link. Theproposed design methodology has made inverters independent from this only virtual linkof communication due to which the reliability of a system has increased. The proposeddesign technique has given very good results in a simulation run. When the Simulinkmodel was run in parallel connected inverter with dierent line impedances, it was asuccess as both inverters started operating with same droop values as they were sharingan equal load. The most important test was with dierent line impedances because inconventional droop control it is dicult for inverters to keep their synchronism withdierent line impedances and an unequal load sharing make inverters to deviate fromtheir nominal values and to generate dierent tracking signals for each set. This problemhas been successfully solved with estimated droop control as in this method each inverterset its droop gains according to its output power, which helps an inverter to operate atnominal values with dierent droop gains and line impedance.

Place, publisher, year, edition, pages
2013. , p. 100
National Category
Control Engineering
Identifiers
URN: urn:nbn:se:kau:diva-30794OAI: oai:DiVA.org:kau-30794DiVA, id: diva2:682929
External cooperation
Fraunhofer IWES, Kassel Germany
Subject / course
Electrical Engineering
Presentation
2013-11-29, 21D302, Karlstad University, Universitetsgatan 2, Karlstad, 16:30 (English)
Supervisors
Examiners
Available from: 2014-01-07 Created: 2013-12-30 Last updated: 2014-01-07Bibliographically approved

Open Access in DiVA

Faisal(8699 kB)1900 downloads
File information
File name FULLTEXT01.pdfFile size 8699 kBChecksum SHA-512
91feff99d812befccefee7f1071bf0a07203608dac051fce063719c525780942464d56d322c84528d475948428a55e905eb4260b826debd41468e015574b13d1
Type fulltextMimetype application/pdf
Arkivfil(8562 kB)2165 downloads
File information
File name FULLTEXT02.pdfFile size 8562 kBChecksum SHA-512
40315d4815657610ada5502464ab8f39e634780638ff74d730b65ead0c345ce9c398904bc21e585013be8ef45426396b499cb11e3172f4af7befaae3757e787b
Type fulltextMimetype application/pdf

By organisation
Department of Physics and Electrical Engineering
Control Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 4371 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 2059 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf