Consistency in reference radiotherapy dosimetry: resolution of an apparent conundrum when Co-60 is the reference quality for charged-particle and photon beams
Stockholm University, Faculty of Science, Department of Physics.
2013 (English)In: Physics in Medicine and Biology, ISSN 0031-9155, E-ISSN 1361-6560, Vol. 58, no 19, p. 6593-6621Article in journal (Refereed) Published
Abstract [en]

Substantial changes in ion chamber perturbation correction factors in Co-60 gamma-rays, suggested by recent Monte Carlo (MC) calculations, would cause a decrease of about 1.5% in the reference dosimetry of all types of charged particles (electrons, protons and heavier ions) based on calculated k(Q) values. It has gone largely unnoticed that the ratio of calibration coefficients N-D,N-w,N-Co60 and N-K,N-air,N-Co60 yields an experimental value of F-ch,F-Co60 = (s(w-air) pch)(Co60) through N-D,N-air,N-Co60. Coefficients provided by the IAEA and traceable to the BIPM for 91 NE-2571 chambers result in an average F-ch,F-Co60 which is compared with published (and new) MC simulations and with the value in IAEA TRS-398. It is shown that TRS-398 agrees within 0.12% with the experimental F-ch,F-Co60. The 1.5% difference resulting from MC calculations (1.1% for the new simulations) cannot be justified using current fundamental data and BIPM standards if consistency in the entire dosimetry chain is sought. For photons, MC k(Q) factors are compared with TRS-398. Using the same uncertainty for W-air, the two sets of data overlap considerably. Experimental k(Q) values from standards laboratories lie between the two sets of calculated values, showing no preference for one set over the other. Observed chamber-to-chamber differences, that include the effect of waterproof sleeves (also seen for Co-60), justify the recommendation in TRS-398 for k(Q) values specifically measured for the user chamber. Current developments on I-values for the stopping powers of water and graphite are presented. A weighted average I-water = 78 +/- 2 eV is obtained from published experimental and DRF-based values; this would decrease sw-air for all types of radiotherapy beams between 0.3% and 0.6%, and would consequently decrease the MC derived F-ch,F-Co60. The implications of a recent proposal for I-graphite = 81 eV are analysed, resulting in a potential decrease of 0.7% in N-K,N-air,N-Co60 which would raise the experimental F-ch,F-Co60; this would result in an increase of about 0.8% in the current TRS-398 value when referred to the BIPM standards. MC derived F-ch,F-Co60 using new stopping powers would then agree at a level of 0.1% with the experimental value, confirming the need for consistency in the dosimetry chain data. Should world average standards be used as reference, the figures would become +0.4% for TRS-398 and -0.3% for the MC calculation. F-ch,F-Q calculated for megavoltage photons using new stopping powers would decrease by between 0.2% and 0.5%. When they enter as a ratios in k(Q), differences with MC values based on current key data would be within 0.2% but their discrepancy with k(Q) experimental photon values remains unresolved. For protons the new data would require an increase in W-air,W-Q of about 0.6%, as this is inferred from a combination of calorimetry and ionometry. This consistent scenario would leave unchanged the current TRS-398 k(Q) (NE-2571) data for protons, as well as for ions heavier than protons unless new independent W-air,W-Q values become available. Also in these advanced radiotherapy modalities, the need for maintaining data consistency in an analysis that unavoidably must include the complete dosimetry chain is demonstrated.

Place, publisher, year, edition, pages
2013. Vol. 58, no 19, p. 6593-6621
National Category
Radiology, Nuclear Medicine and Medical Imaging Biomedical Laboratory Science/Technology
Identifiers
URN: urn:nbn:se:su:diva-95075DOI: 10.1088/0031-9155/58/19/6593ISI: 000324573600001PubMedID: 24018471Scopus ID: 2-s2.0-84884603302OAI: oai:DiVA.org:su-95075DiVA, id: diva2:658724
Note

AuthorCount:4;

Available from: 2013-10-22 Created: 2013-10-21 Last updated: 2022-10-04Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Search in DiVA

By author/editor
Andreo, Pedro
By organisation
Department of Physics
In the same journal
Physics in Medicine and Biology
Radiology, Nuclear Medicine and Medical ImagingBiomedical Laboratory Science/Technology

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 219 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf