Parametric Images of Myocardial Viability Using a Single 15O-H2O PET/CT Scan
Vise andre og tillknytning
2011 (engelsk)Inngår i: Journal of Nuclear Medicine, ISSN 0161-5505, E-ISSN 1535-5667, Vol. 52, nr 5, s. 745-749Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Perfusable tissue index (PTI) is a marker of myocardial viability and requires acquisition of transmission, 15O-CO, and 15O-H2O scans. The aim of this study was to generate parametric PTI images from a 15O-H2O PET/CT scan without an additional 15O-CO scan.

Methods:

Data from 20 patients undergoing both 15O-H2O and 15O-CO scans were used, assessing correlation between PTI based on 15O-CO (PTICO) and on fitted blood volume fractions (PTIVb). In addition, parametric PTIVb images of 10 patients undergoing 15O-H2O PET/CT scans were generated using basis-function methods and compared with PTIVb obtained using nonlinear regression. Simulations were performed to study the effects of noise on PTIVb.

Results:

Correlation between PTICO and PTIVb was high (r2 = 0.73). Parametric PTIVb correlated well with PTIVb obtained using nonlinear regression (r2 = 0.91). Simulations showed low sensitivity to noise (coefficient of variation < 10% at 20% noise).

Conclusion:

Parametric PTI images can be generated from a single 15O-H2O PET/CT scan.

sted, utgiver, år, opplag, sider
2011. Vol. 52, nr 5, s. 745-749
HSV kategori
Identifikatorer
URN: urn:nbn:se:uu:diva-189079DOI: 10.2967/jnumed.110.085431PubMedID: 21498530OAI: oai:DiVA.org:uu-189079DiVA, id: diva2:580602
Tilgjengelig fra: 2012-12-23 Laget: 2012-12-23 Sist oppdatert: 2017-12-06bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Søk i DiVA

Av forfatter/redaktør
Lubberink, Mark
I samme tidsskrift
Journal of Nuclear Medicine

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 413 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf