Digitala Vetenskapliga Arkivet

Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Comparative study on preliminary breakdown pulse trains observed in Johor, Malaysia and Florida, USA
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Elektricitetslära.
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Elektricitetslära.
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Elektricitetslära.
Vise andre og tillknytning
2012 (engelsk)Inngår i: Atmospheric research, ISSN 0169-8095, E-ISSN 1873-2895, Vol. 117, s. 111-121Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

In this paper, the preliminary breakdown (PB) pulse train preceding the negative first return stroke (RS) is recorded using a broad band antenna system. These analyses were carried out in Johor Bahru, Malaysia and Florida, United States. This is a novel initiative at examining and identifying the characteristics of the PB pulse trains in the negative cloud-to-ground flashes observed in Malaysia. The arithmetic mean of the total pulse train duration is 12.3 ms and the weighted arithmetic mean of the pulse durations and interpulse intervals are 11 mu s and 152 mu s, respectively. The arithmetic mean ratio between the maximum peak amplitude of the PB pulse and the peak RS electric field was 27.8%, and the corresponding value in Florida was 29.4%. The arithmetic mean of the time duration between the most active part of the pulse train, and the RS was 57.6 ms in Malaysia and 22 ms in Florida. A qualitative comparison of our results with those obtained earlier in Sri Lanka. Sweden and Finland supports the hypothesis that the PBP/RS ratio is higher in the northern regions compared to the tropical regions. (C) 2012 Elsevier B.V. All rights reserved.

sted, utgiver, år, opplag, sider
2012. Vol. 117, s. 111-121
Emneord [en]
Preliminary breakdown pulses, PB/RS ratio, PB-RS separation
HSV kategori
Forskningsprogram
Teknisk fysik med inriktning mot elektricitetslära
Identifikatorer
URN: urn:nbn:se:uu:diva-184450DOI: 10.1016/j.atmosres.2012.01.012ISI: 000309300100015OAI: oai:DiVA.org:uu-184450DiVA, id: diva2:566735
Tilgjengelig fra: 2012-11-09 Laget: 2012-11-07 Sist oppdatert: 2017-12-07bibliografisk kontrollert
Inngår i avhandling
1. Characterizations of ground flashes from tropic to northern region
Åpne denne publikasjonen i ny fane eller vindu >>Characterizations of ground flashes from tropic to northern region
2014 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig) [Kunstnerisk arbeiden]
Abstract [en]

This thesis portrays new information concerning the cloud-to-ground (CG) lightning flashes or ground flashes produced by thunderclouds. It emphasizes the importance of characterizing lightning studies as the relationship between lightning mechanisms, and of incorporating the influence of geographical location, latitude and storm type. Sweden, Malaysia and USA were chosen as the main locations for field experiments in 2009 to 2011 to gather a significant number of negative and positive CG flashes. This work provided data on a total of 1792 CG lightning flashes (1685 negative and 107 positive ones) from a total of 53 thunderstorms by monitoring both the slow and the fast electric field and the narrowband radiation field at 3 and 30 MHz signals simultaneously. This thesis is comprised of: (i) the relationship of the Low Positive Charge Region (LPCR) and Preliminary Breakdown Pulse (PBP) trains to the occurrence of negative CG, (ii) slow field changes generated by preliminary breakdown processes in positive and negative ground flashes, and (iii) the occurrence of positive and negative ground flashes. It was revealed that the PBP train appeared have a higher strength in the in Sweden. The strength of the PBP train was caused by the LPCR; in contrast,  weak PBP trains were characteristic in tropical countries constituting insignificant LPCR and needing little energy to break the “blocking” agent to allow the flash to propagate downward to the ground. The second contribution concerns the characteristics of the PBP train mentioned; this includes novel information for Malaysia. Further, it is stated that there are some different characteristics in the PBP trains in Johor, Malaysia and Florida, USA. The studies of slow field changes generated by preliminary breakdown processes clarifies unclear features concerning the starting position of slow field changes generated by preliminary breakdown processes in positive and negative ground flashes. It was found that the slow field changes did not occur before the initial process of the commencement of preliminary breakdown. Single-station electric field measurements incorporating narrowband radiation field measurement and high resolution transient recording (12 bits) with an accuracy of several nanoseconds, allows one to distinguish between the intracloud activities and the preceding processes of ground flashes. The results for the interstroke intervals, amplitude distribution of subsequent return-stroke (SRS) and the number of strokes per flash in the tropics, subtropics and northern regions were similar. Finally, a significant number of positive return-stroke (RS) electric fields provided statistically significant information on the characteristics of these strokes.

sted, utgiver, år, opplag, sider
Uppsala: Acta Universitatis Upsaliensis, 2014. s. 78
Serie
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology, ISSN 1651-6214 ; 1145
Emneord
Positive/negative cloud-to-ground lightning flashes, Initiation position, slow field changes, close ground flashes, preliminary breakdown process
HSV kategori
Forskningsprogram
Teknisk fysik med inriktning mot atmosfäriska urladdningar
Identifikatorer
urn:nbn:se:uu:diva-222838 (URN)978-91-554-8946-5 (ISBN)
Disputas
2014-06-03, Häggsalen, Ångström Laboratory, Lägerhyddsvägen 1, Uppsala, 10:00 (engelsk)
Opponent
Veileder
Forskningsfinansiär
Swedish Research Council, 621-2006-4299
Tilgjengelig fra: 2014-05-12 Laget: 2014-04-15 Sist oppdatert: 2018-05-28

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Søk i DiVA

Av forfatter/redaktør
Baharudin, Zikri A.Cooray, Vernon
Av organisasjonen
I samme tidsskrift
Atmospheric research

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 439 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf