Design and construction of a mobile equipment for thermal response test in borehole heat exchangers
KTH, Skolan för industriell teknik och management (ITM), Energiteknik, Tillämpad termodynamik och kylteknik.
2012 (engelsk)Independent thesis Advanced level (degree of Master (Two Years)), 20 poäng / 30 hpOppgave
Abstract [en]

In 2010, the Ground Source Heat Pumps (GSHPs) market in the European Union went up over one million (1 014 436 units at the end of 2010 according to EUROBSERV’ER 2011). In 2011, it was estimated around 1.25 million according to Bayer et al. (2012). With more than 378 000 units installed in 2010, according to the Swedish heat pump association (SVEP), the Swedish GSHPs market was the first in the EU. As for the French GSHPs market, it was estimated to 151 938 units in service in 2010, which propelled France at the third rank in the EU. However, despite a relatively important number of GSHPs installed in the whole EU, since 2008 GSHP sales have shrank. Even Sweden which has been the most competitive country sees its GSHP sales decline in the first quarter of 2012 (EUROBSERV’ER 2011).

This report is the achievement of my Master of Science Thesis project. It also represents the end of my studies at INSA Lyon in France and concludes my degree in Energetic and Environment Engineering. This report deals with the improvement of a heat injection apparatus which is available at KTH (Royal Institute of Technology). This equipment is better known as Thermal Response Test (TRT) apparatus. This kind of equipment improves Borehole Heat Exchangers (BHE) design in terms of size and cost benefits. This technology is generally used to design GSHP installations in both domestic and industrial purposes. It allows to determine really important thermal BHE parameters: the thermal conductivity of the ground and the borehole thermal resistance. The report covers a theoretical description of TRT experiments, the reasons and objectives of such a project, the apparatus design and its construction. The last part is dedicated to a first experimental laboratory results and some problems met during the project course. 

sted, utgiver, år, opplag, sider
2012.
Emneord [en]
Thermal Response Test, Borehole Heat Exchanger, Ground Source Heat Pump
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-99558OAI: oai:DiVA.org:kth-99558DiVA, id: diva2:542413
Uppsök
Technology
Veileder
Examiner
Tilgjengelig fra: 2012-08-15 Laget: 2012-08-01 Sist oppdatert: 2012-08-02bibliografisk kontrollert

Open Access i DiVA

Kamarad Anthony EGI-2012-054MSC(9815 kB)261 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 9815 kBChecksum SHA-512
3744f60263cad3c7d60b028893c77fe1206e8703ea3c461e0f3785f387111f17c23030713e5cb04391f962d849e2cf1b480f835b0f92f3c6a7135cdd3c2c981c
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 261 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 2820 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf