Echo-guided presentation of the aortic valve minimises contrast exposure in transcatheter valve recipients
Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
Linköpings universitet, Institutionen för medicin och hälsa, Thoraxkirurgi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Thorax-kärlkliniken i Östergötland.
Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Thorax-kärlkliniken i Östergötland.
Linköpings universitet, Institutionen för medicin och hälsa, Kardiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Kardiologiska kliniken US.
Vise andre og tillknytning
2011 (engelsk)Inngår i: Catheterization and cardiovascular interventions, ISSN 1522-1946, E-ISSN 1522-726X, Vol. 77, nr 2, s. 272-275Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

OBJECTIVES:

We have developed a method using transthoracic echocardiography in establishing optimal visualization of the aortic root, to reduce the amount of contrast medium used in each patient.

BACKGROUND:

During transcatheter aortic valve implantation, it is necessary to obtain an optimal fluoroscopic projection for deployment of the valve showing the aortic ostium with the three cusps aligned in the beam direction. This may require repeat aortic root angiograms at this stage of the procedure with a high amount of contrast medium with a risk of detrimental influence on renal function.

METHODS:

We studied the conventional way and an echo guided way to optimize visualisation of the aortic root. Echocardiography was used initially allowing easier alignment of the image intensifier with the transducer's direction.

RESULTS:

Contrast volumes, radiation/fluoroscopy exposure times, and postoperative creatinine levels were significantly less in patients having the echo-guided orientation of the optimal fluoroscopic angles compared with patients treated with the conventional approach.

CONCLUSION:

We present a user-friendly echo-guided method to facilitate fluoroscopy adjustment during transcatheter aortic valve implantation. In our series, the amounts of contrast medium and radiation have been significantly reduced, with a concomitant reduction in detrimental effects on renal function in the early postoperative phase.

sted, utgiver, år, opplag, sider
2011. Vol. 77, nr 2, s. 272-275
Emneord [en]
aortic valve stenosis;heart valve prosthesis;transthoracic echocardiography
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-74503DOI: 10.1002/ccd.22747PubMedID: 20824753OAI: oai:DiVA.org:liu-74503DiVA, id: diva2:486108
Tilgjengelig fra: 2012-01-30 Laget: 2012-01-30 Sist oppdatert: 2017-12-08

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Søk i DiVA

Av forfatter/redaktør
Ahn, HenrikNielsen, Niels-ErikNylander, EvaJanerot-Sjöberg, BirgittaSandborg, MichaelWallby, Lars
Av organisasjonen
I samme tidsskrift
Catheterization and cardiovascular interventions

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 816 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf